Datasheet

ENCODER | SICK
Subject to change without notice
6 8015321/2016-01-25
DBS36 Core INCREMENTAL ENCODERS
Electrical data
Electrical interface
4.5 V ... 5.5 V, TTL/RS422
7 V ... 30 V, TTL/RS422
7 V ... 30 V, HTL Push Pull
7 V… 27 V, HTL Push Pull, 3 channel
4.5 V ... 5.5 V, Open Collector NPN, 3 channel
4.5 V ... 30 V, Open Collector NPN, 3 channel
Connection type
Cable, 5 or 8-wire, universal, 0.5 m
2)
Cable, 5 or 8-wire, universal, 1.5 m
2)
Cable, 5 or 8-wire, universal, 3 m
2)
Cable, 5 or 8-wire, universal, 5 m
2)
Cable, 5 or 8-wire, universal, 10 m
2)
Cable, 8-wire with male connector M12, universal, 0.5 m
Cable, 8-wire with male connector M23, universal, 0.5 m
1)
Operating current without load
4.5 V...5.5 V, TTL/RS422 ≤ 50 mA
4.5 V ... 5.5 V, Open Collector NPN, 3 channel ≤ 50 mA
Max. power consumption without load
7 V ... 30 V, TTL/RS422 < 0.5 W
7 V ... 30 V, HTL Push Pull < 0.5 W
7 V… 27 V, HTL Push Pull, 3 channel < 0.5 W
4.5 V ... 30 V, Open Collector NPN, 3 channel < 0.5 W
Max. load current
Open Collector ≤ 30 mA
TTL/HTL ≤ 30 mA
Maximum output frequency
300 kHz
Reference signal, number
1
Reference signal, position
90 degrees electric, logically gated with A and B
Reverse polarity protection
4.5 V ... 5.5 V, TTL/RS422
7 V ... 30 V, TTL/RS422
l
7 V ... 30 V, HTL Push Pull
l
7 V… 27 V, HTL Push Pull, 3 channel
l
4.5 V ... 5.5 V, Open Collector NPN, 3 channel
l
4.5 V ... 30 V, Open Collector NPN, 3 channel
l
Short-circuit protection of outputs
3)
4.5 V ... 5.5 V, TTL/RS422
l
7 V ... 30 V, TTL/RS422
l
7 V ... 30 V, HTL Push Pull
l
7 V… 27 V, HTL Push Pull, 3 channel
4.5 V ... 5.5 V, Open Collector NPN, 3 channel
l
4.5 V ... 30 V, Open Collector NPN, 3 channel
l
MTTFd: mean time to dangerous failure
600 years (EN ISO 13849-1)
4)
1)
M23 male connector for central mounting
2)
Number of wires depending on electrical interface: Interface A, C, E: 8-wire; Interface G, P, R: 5-wire.
3)
Short-circuit protection is only guaranteed when Us and GND are connected correctly.
4)
This product is a standard product and does not constitute a safety component as dened in the Machinery Directive. Calculation based on nominal load of de-
vices, average ambient temperature 40 °C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no.
8015532".