Datasheet

A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
C4C-SA15030A10000, C4C-EA15030A10000 | deTec
SAFETY LIGHT CURTAINS
Ordering information
System part Type Part no.
Sender C4C-SA15030A10000 1211505
Receiver C4C-EA15030A10000 1211506
Other models and accessories www.sick.com/deTec
Detailed technical data
Features
Items supplied
Sender
Receiver
Test rod with diameter corresponding to the resolution of the safety light curtain
Safety instruction
Mounting instructions
Operating instructions for download
Compatible sender
<a href="https://www.sick.com/1211505" target="_blank">1211505</a>
Compatible receiver
<a href="https://www.sick.com/1211506" target="_blank">1211506</a>
Application
Normal industrial environment
Resolution
30mm
Protective field height
1,500mm
Scanning range
15m
Response time
13ms
No blind zones
Yes
Synchronization
Optical synchronisation
Safety-related parameters
Type
Type 4(IEC61496-1)
Safety integrity level
SIL3 (IEC61508)
SILCL3 (IEC62061)
Category
Category 4(ISO13849-1)
Performance level
PLe(ISO13849-1)
PFH
D
(mean probability of a dangerous fail-
ure per hour)
3.7x 10
-9
T
M
(mission time)
20years (ISO13849-1)
Safe state in the event of a fault
At least one OSSD is in the OFF state.
2 OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK Online data sheet | 2018-07-13 15:53:34
Subject to change without notice