Datasheet
C4C-SA04530A10000, C4C-EA04530A10000 | deTec
SAFETY LIGHT CURTAINS
L
1,800 1,812
1,950 1,962
2,100 2112
Connection diagram
deTec4 Core safety light curtain to UE48-2OS safety relay
S34 S21S35 S22
S33 S12S11 S31
14A2 24 32
13A1 23 31
UE48-2OS2D2
K1 K2
S1
k1
k2
OSSD1
OSSD2
n.c.
GND
+24V
1
2
3
4
5
+24V
n.c.
GND
n.c.
n.c.
1
2
3
4
5
24 V DC
0 V DC
E114585/01/2014-05-08
Task
Connection of a deTec4 Core safety light curtain to a UE48-2OS.
Operating mode: With restart interlock and external device monitoring
Mode of operation
When the light path is clear, the OSSD1 and OSSD2 outputs carry voltage. When K1 and K2 are in a fault-free de-energized posi-
tion, the system can be switched on and waits for an input signal/switch-on signal. The UE48-2OS is switched on by pressing and
then releasing the S1 pushbutton. The outputs (contacts 13- 14and 23- 24) switch the K1 and K2 contactors on. When one or
more light beams are interrupted, the OSSD1 and OSSD2 outputs switch off the UE48-2OS. Contactors K1 and K2 are switched
off.
Fault analysis
Cross-circuits and short-circuits of the OSSDs are recognized and lead to the locking state (lock-out). A malfunction with one of the
K1 or K2 contactors is detected. The shut-down function is retained. In the event of manipulation (e.g., jamming) of the S1 push-
button, the UE48-2OS will not re-enable the output current circuits.
Comments
1)
Output circuits: These contacts must be incorporated into the control such that the dangerous state is brought to an end if the
output circuit is open. For categories 4and 3, they must be incorporated on two channels (x, y paths). Single-channel incorporation
into the control (z path) is only possible with a single-channel control and taking the risk analysis into account.
2018-07-13 15:53:34 | Online data sheet
Subject to change without notice
OPTO-ELECTRONIC PROTECTIVE DEVICES | SICK 5