User's Manual

M3P U-series AC EV Charging Station User Manual
9
4.3. Technical specifications
4.3.1. Electrical parameters
1 Input Voltage Level 2, 240VAC
2 Rated frequency 50/60 Hz
3 Branch breaker
It is recommended that a charger should be equipped with dedicated
MCB circuit for power supply
4 Input circuit terminal L1/ L2 / GND
4.3.2. Input plug & cable
Input plug & cable
Plug: NEMA 14-50P; Cable: 4×8 AWG, 300mm, copper.
X: L1;
Y: L2;
W: No connect terminal;
G: Ground.
4.3.3. Functional description
1 Charging mode Mode 3
2 Charging control
Local: “Plug-and-charge” or “swipe card-controlled”
Remote: smart phone APP control (Operators build own APP).
3 Indicator lights
4 LED lights
(indicate 4 status include power, connect, charging and fault)
4
Communication
interface
Ethernet (RJ-45 interface), WiFi (2.4GHz)
5 Communication protocol
OCPP 1.6
6 Safety protection
Surge protection, over temperature, over/under voltage, over current,
ground protection
4.3.4. Mechanical parameters
1 Mounting Wall-mounted
2 Charging connector SAE J1772 (or IEC 62196-2, Type 1)
3 Charging cable length
5m
4 Dimension (H×W×D) 309mm × 215mm × 114mm (as shown in Fig. 3-1)