M3P U-series Level 2 AC EV Charger User Manual DOC ID: UM211401.
IMPORTANT SAFETY INSTRUCTIONS WARNING - When using electric products, basic precautions should always be followed, including the following. This manual contains important instructions for Models M3P132U and M3P140U that shall be followed during installation, operation and maintenance of the unit. 1. Read all the instructions before using this product. 2. This device should be supervised when used around children. 3. Do not put fingers into the electric vehicle connector. 4.
CONSIGNES DE SÉCURITÉ IMPORTANTES AVERTISSEMENT - Lors de l'utilisation de produits électriques, des précautions de base doivent toujours être suivies, y compris les suivantes. Ce manuel contient des instructions importantes pour les modèles M3P132U et M3P140U qui doivent être suivies pendant l'installation, l'utilisation et la maintenance de l'unité. 1. Lisez toutes les instructions avant d'utiliser ce produit. 2. Cet appareil doit être surveillé lorsqu'il est utilisé à proximité d'enfants. 3.
M3P U-series AC EV Charging Station User Manual CONTENTS 1. ABBREVIATIONS 2 2. SAFETY NOTES 3 2.1. Safety signs 3 2.2. Installation 4 2.3. Maintenance 4 2.4. Operating 5 3. STANDARDS 6 3.1. Reference standard 6 3.2. Charging mode 6 3.3. Charging connection 6 3.4. Charging connector 7 4. PRODUCT INFORMATION 8 4.1. General 8 4.2. Block diagram 8 4.3. Technical specifications 9 4.4. Nameplate 5. INSTALLATION INSTRUCTIONS 10 12 5.1. Transport or movement 12 5.2.
M3P U-series AC EV Charging Station User Manual 1.
M3P U-series AC EV Charging Station User Manual 2. SAFETY NOTES 2.1. Safety signs The following warning signs, mandatory signs and information signs are used in the user manual, on and in the M3P EV Charger: Les panneaux d'avertissement, panneaux obligatoires et panneaux d'information suivants sont utilisés dans le manuel d'utilisation, sur et dans la station de charge M3P EV: 2.1.1. Warning Signs CAUTION: Warning of electrical hazards.
M3P U-series AC EV Charging Station User Manual Must wear a safety helmet Doit porter un casque de sécurité 2.2. Installation Safety protection must be done when installing the EV Charger. Une protection de sécurité doit être effectuée lors de l'installation de la station de charge EV. Installation must be carried out by personnel with professional qualification, otherwise there is a risk of electric shock.
M3P U-series AC EV Charging Station User Manual It is recommended that routine safety inspection visits to Charger be conducted at least once a week. Il est recommandé que le chargeur fasse l'objet d'un contrôle de sécurité au moins une fois par semaine. Do not put inflammable, explosive or combustible materials, chemicals, combustible steam and other dangerous goods near the Charger, otherwise there is a risk of fire.
M3P U-series AC EV Charging Station User Manual 3. STANDARDS 3.1. Reference standard The M3P U-series AC EV Charger is designed according to IEC standards. The standards of this series of products include: IEC 61851-1:2017, Electric vehicle conductive charging system - Part 1: General requirements IEC 62196-2:2016, Plugs, socket-outlets, vehicle connectors and vehicle inlets – Conductive charging of electric vehicles – Part 2: Dimensional compatibility and interchangeability requirements for a.c.
M3P U-series AC EV Charging Station User Manual 3.4. Charging connector The charging connector of M3P U-series products meet IEC 62196-2, type 1 (Schematic diagram shown as Fig. 3-2). The charging object of M3P U-series products are the electric vehicle with type 1 charging socket (Vehicle inlet) described in IEC 62196-2. (a) type 1 socket (b) type 1 plug Fig.
M3P U-series AC EV Charging Station User Manual 4. PRODUCT INFORMATION 4.1. General Welcome to use the M3P U-series AC EV Charger produced by our company. The Shape & Dimensions of M3P U-series AC EV Charger shown as Fig. 4-1. M3P U-series AC EV Charger provides a friendly HMI, with the corresponding control, measuring and communication functions, belongs to the special AC power supply device for EV.
M3P U-series AC EV Charging Station User Manual 4.3. Technical specifications 4.3.1. Electrical parameters 1 Input Voltage Level 2, 240VAC 2 Rated frequency 50/60 Hz 3 Branch breaker It is recommended that a charger should be equipped with dedicated MCB circuit for power supply 4 Input circuit terminal L1/ L2 / GND 4.3.2. Input plug & cable Plug: NEMA 14-50P; Cable: 4×8 AWG, 300mm, copper. X: L1; Y: L2; W: No connect terminal; G: Ground. Input plug & cable 4.3.3.
M3P U-series AC EV Charging Station User Manual 5 Weight ≤ 6kg 6 Color White and Gray 7 Material PC 8 Enclosure rated NEMA Type 4 4.3.5. Ambient conditions 1 Altitude ≤ 2000m 2 Storage temperature -40 ~ 75℃ 3 Operating temperature -30 ~ 55℃ 4 Relative humidity ≤ 95%RH, No water droplet condensation 5 Vibration < 0.5G, No acute vibration and impaction 6 Installation location Indoor or outdoor, good ventilation, no flammable, explosive gases 4.4.
M3P U-series AC EV Charging Station User Manual Fig.
M3P U-series AC EV Charging Station User Manual 5. INSTALLATION INSTRUCTIONS 5.1. Transport or movement When transporting or moving, please pay attention to the following points to ensure product safety: a) This product is electrical equipment. It should be handled with care to avoid violent vibration and impact. b) The front panel of the product is a glass panel, which cannot be used as a stressed part for handling.
M3P U-series AC EV Charging Station User Manual Fig. 5-1 Wall-mounting accessories 5.2.2. Inspection & confirm When unpacking, please carefully confirm the following points: a) Whether the accessories are missing according to the packing list. b) Whether there is any damage during transportation. If any damage or missing parts are found, please do not start the machine and inform the supplier.
M3P U-series AC EV Charging Station User Manual 5.3. Installation preparation 5.3.1. Safety notes for installation Refer to 2.3 for more safety notes. Installation and wiring should be done by personnel with professional qualification, otherwise, hazardous electric shock may result. Make sure input power supply is entirely disconnected before wiring; otherwise, hazardous electric shock may result.
M3P U-series AC EV Charging Station User Manual b) Refer to 4.4.4 for more ambient conditions. c) It is suggested that the Charger should be installed in a place with good ventilation, no direct sunlight and shelter from wind and rain. d) In order to ensure good ventilation condition, you should mount the Charger vertically and leave enough space. e) If you purchase products with floor mounted accessories, the installation effect is similar to that of wall mounted product. 5.4.
M3P U-series AC EV Charging Station 5.4.2. User Manual Step 2: Hang the charger on the accessory-D Secure mounting accessories(A+B) to the charger; Follow the arrow, and hang the charger on accessories-D. Fig. 5-3 Hang the charger on the accessories-D 5.4.3. Step 3: Wiring network wire If the CMS is to be connected through the network cable, put the network wire through the network wire protective ring, then crimp the RJ-45 head, and then insert it into the network cable interface. Fig.
M3P U-series AC EV Charging Station b) User Manual Pass the input cable through the cable protective ring, connect the power cable to the input terminals; Reset the terminal box cover. It is recommended to use flame retardant rubber copper core cable as the input cable, pass the cable through the input interface of the Charger, then fix the Live wire, Neutral wire and GND wire to the corresponding terminals, and finally fix the cable. 5.4.4.
M3P U-series AC EV Charging Station User Manual 6. OPERATION 6.1. Power on After the Charger is installed and confirmed to be correct, the MCB at the input side is switched on, and indicator light is on, and the Charger enters the standby state. 6.2. Human-machine interface 6.2.1. HMI information As shown in Fig. 6-1, the M3P U-series product is configured with multiple human-machine interfaces.
M3P U-series AC EV Charging Station YELLOW 3 BLUE 4 6.2.3. User Manual Fault status. Get the fault code by the cycle flashing of the fault indicator. Twinkle OFF Unconnected to the network ON Connected to the network 1Hz twinkle Normal connection with CMS 5Hz twinkle Configure WiFi network status RFID reader In general, M3P is equipped with RFID card reader as standard, and the charging process can be started and stopped by using the RFID card (shown as Fig. 6-2) configured with the host.
M3P U-series AC EV Charging Station e) User Manual Open the esptouch APP, enter the password for the WiFi network name (shown as Fig. 6-3), and keep the phone in the esptouch APP, do not exit. Fig. 6-3 APP interface f) Press and hold the WiFi configuration button until the indicator light flashes at 5Hz frequency, and the Charger enters the WiFi network configuration state. Click the "CONFIRM" button on the phone. g) Charger automatically configures WiFi network.
M3P U-series AC EV Charging Station User Manual Fig. 6-4 WiFi configuration button 6.4. Start charging a) Park the electric car into place, turn off the engine, and put the car under braking. b) Pick off the charging connector and is shown as Fig. 6-5. c) Plug the charging connector into the AC charging socket of the electric vehicle and the indicator light of the Fig.6-5 Pick off the charging connector Charger will be light on.
M3P U-series AC EV Charging Station b) User Manual Operation of manual stoppage: press the unlock button of the remote key of the electric vehicle, the vehicle will stop charging (requires the support of the electric car), if the charging is not stopped, pull connector out the vehicle, the indicator will go off, and the charging will stop automatically. Fig. 6-6 pull connector out the vehicle c) Pull the connector out of the vehicle to complete charging process.
M3P U-series AC EV Charging Station User Manual 7. FAULT HANDLING AND MAINTENANCE 7.1. Fault Handling The Charger is automatically protected in the event of the fault. The fault information and handling methods are as follows. indicator information Fault category Handling Method CP voltage anomaly Fault code 11: Check that the connector is properly connected to the electric vehicle, pull and plug the connector and try charging again.
M3P U-series AC EV Charging Station indicator information User Manual Fault category Handling Method Flash slowly twice and fast 1 times Electric vehicle response timeout Fault code 21: Make sure that the charging connector is properly connected to the car, pull out and retry, or the car is full charge.
M3P U-series AC EV Charging Station User Manual WARRANTY AGREEMENT 1. The scope of warranty refers to the product itself. 2. The warranty period is 12 months. During the warranty period, the company will repair the product free of charge in case of failure or damage (determined by the company's technical personnel) under normal use. 3. The starting time of warranty period is the date of product manufacture. 4.
FCC Warning Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Any change without prior notice! Sichuan Weiyu Electric Co., Ltd Address: No.1, Tumenjiang Road (C2# Building, Tianyu Science & Technology Park), Deyang, Sichuan, P. R. China P.C.: 618000 Tel: +86-0838-6926969 Web: www.wyevcharger.com www.weeyuevse.com E-mail:support@ wyevcharger.com support@weeyuevse.