Installation Instructions
WF-M601-UWS3
WiFi Module
Sichuan AI-Link Technology Co., Ltd. page 11 of 16
9. Software Requirements
The driver supports the following operating systems: Linux, Microsoft Windows XP, Vista and Win7.
Mfg. software tool version is MT7601 USB QA V1.0.9.0 or later.
10. Refelow Standard Condition
11. Mechanical, Environmental and Reliability Tests
Test Items
Test Conditions
Qty
Criteria Condition
4-1
Drop test
The packed samples within
100Kg can be tested
Drop height:
Face Side: 800/600/450mm
Edge line: 600/450/350mm
Drop time: 1 each Face and
edge.
1xBox
After drop test, the outer box and inner box will
not been broken by appearance visual
inspection.
4-2
Vibration test
X-Y-Z direction, first
Frequency changing from
10Hz to 30Hz to 10Hz
,amplitude 0.75mm, 5 times
vibrations, then frequency
Changing from 30Hz to 55
Hz to 30 Hz, amplitude
0.15mm, 5 time vibration.
3
After test, the Appearance, Power EVM and
Frequency error shall be satisfied with the
specification.
4-3
Impact test
Impact acceleration:
50m/sec2;
Impact duration: 16ms;
Impact times: 1000.
3
After test, the Appearance, Power EVM and
Frequency error shall be satisfied with the
specification.