Installation Guide

FUNCTION฀SELECTOR฀JUMPER฀SETTINGS:
J1฀ MASTER฀SWITCH
1-2฀Latching
2-3฀Momentary
Factory฀setting฀is฀1-2฀for฀all฀four฀Jumpers
OPERATION
Every฀time฀the฀position฀of฀the฀REMOTE฀SWITCH฀changes,฀the฀Motorized฀Valve(s)฀rotate฀
to the opposite position. In addition, if connected, the heater thermostat setting changes
from฀LOW฀to฀HIGH฀or฀HIGH฀to฀LOW.
TROUBLE SHOOTING
Problem Cause Solution
1.฀Nothing฀works. a.฀No฀power฀to฀transformer฀ Check฀power฀supply
b.฀120฀Volt฀is฀connected฀to฀ Connect฀120฀Volt฀supply฀to฀Black
฀฀฀฀240฀Volt฀leads฀ and฀White฀leads
c.฀240฀Volt฀was฀connected฀to฀ Replace฀defective฀control฀unit
฀฀฀120฀Volt฀transformer฀leads.
2.฀Remote฀installed฀฀ a.฀Jumper฀J1฀is฀on฀pins฀2-3฀ Place฀Jumper฀J1฀on฀Pins฀1-2
฀฀฀฀Actuator฀Switch฀will฀ ฀฀฀฀or฀missing.
not operate
equipment.
3.Wired฀remote฀is฀฀ a.฀Connector฀is฀incorrectly฀฀ Re-attach฀8-pin฀connector
not working attached
b.฀Corroded/dirty฀connector฀ Clean฀connector฀pins.
pins
4.Valve฀actuators฀฀ a.฀Actuators฀are฀out-of-sync฀ Synchronize฀actuators฀(Refer฀to฀฀
฀฀฀฀work฀opposite฀ valve฀actuator฀manual)
pump relay