Installation Guide
This Switching Device is most suited for controlling the shared equipment of Pool-Spa
combinations but it can be also used to control all the equipment typically needed in con-
nection with water features, water gardening solar heating and other similar applications.
The Mechanism is designed to “snap” into most Intermatic panels and outdoor
enclosures in use today and it can be interfaced with other Intermatic products in order
to facilitate a large number of custom applications.
DANGER
WARNING
WIRING INSTRUCTIONS
•DonotpermitsmallchildrentooperateorusethePool/Spaunlesstheyareclosely
supervised at all times.
•TestGROUNDFAULTprotectionregularly.Ifitfailstoreset,DONOTUSETHEPOOLor
SPA!Contactaqualiedservicetechnician.
•AlwaysdisconnectelectricitybeforeservicingthisControlortheequipmentconnectedto
it.
When installing and operating this Product and other associated equipment, basic safety
precautions should always be followed,
• ThisControlmustbeinstalledbyaqualiedperson,accordingtoNationalandLocal
ElectricalCodes.
• InstallthisControlnolessthan5feet(3metersinCanada)frominsideedgeofpool.
USECOPPERCONDUCTORSONLYrated75˚Cminimum.
• Donotexceedthemaximumratingsofindividualcomponents,wiringdevices,and
current carrying capacity of conductors.
• ForControlgrounding,bonding,installingandthewiringofunderwaterlights,referto
Article680oftheNationalElectricalCodeorArticle68oftheCanadianElectricalCode.
• TheControlshouldnotoperateanyequipmentwhichcouldcausebodilyinjuryor
propertydamageshoulditbeactivatedunexpectedly.
GENERAL INFORMATION
Figure 3
1 2 3
VALVE ACTUATOR
CONNECTIONS
1 2
3
SPA
(HIGH)
POOL
(LOW)
COM
HEATER
CONNECTIONS
(SEE FIG. 2)
WIRED
REMOTE
WIRED
REMOTE
FUNCTION
SELECTOR
JUMPERS
SEE NOTE 1
J1
J2
J3
J4
1 2 3
TERMINAL
SCREWS
2
NOTE: High and low voltage wires should not occupy the same conduits and compartments.
Ifneeded,installcorrugatedtubingkit,PartNo.156PA12976Arst(notsupplied).
1. MakepowerconnectionstoTransformer.If120Volt,connectsupplytoBLKandWHT
leads,if240Volt,connectsupplytoBLKandREDleads.Insulate (cap) unused lead.
2. PlugMotorizedValveAcutator(s)intoanypolarizedreceptacle(s)seedrawing.
3. ConnectanyexternalREMOTESWITCHtothetwoBlackandWhitestripedleadsas
shownbelowandapplytheTriggerVoltageofeither120or240VAC.
4. Ifapplicable,makeheaterconnections.Removeterminalblockfromsocketand
dependingonthetypeofheater,followoneofthediagramsonpage3.
5. Ifapplicable,makeRemoteControlconnectiontothe8pinpolarizedreceptacle.
LOW VOLTAGE COMPARTMENT
VALVE
ACTUATORS
HEATER
TERMINALS
JUMPERS
REMOTE
CONTROL
CONNECTOR
REMOTE
SWITCH
TRANSFR.
RED
WHT
BLK
BLK/WHT
POWERINPUT
SEEINSTRUCTION#1
BLK/WHT
TRIGGER
VOLTAGE
SEE
INSTRUCTION#3