User's Manual
ALFOplus 24GHz (North America) - Release 01.05.0x - MN.00395.E - 004 93
Warning It is mandatory to verify with Ethernet tester (not supplied) the proper connectivity of both ends,
in order to avoid autonegotiation problems (as for example 1Gbps full duplex not reached).
Strip jacketing and shield as shown
Fold shield back onto jacketing. Wrap grain wire
one and a half times around the shield. Trim ex-
cess length from drain wire
Untwist pairs and arrange to desired order.
Note: it is recommended to follow TIA-568 spec-
ifications for wiring orientation
Trim conductors at an angle and insert into the
loading bar
Trim excess wire from holder
Insert prepared cable into RJ-45 Plug
Bend strain relief to lay along cable
Crimp plug and strain relief
a
a. Use recommended RJ45 crimping tool.