User's Manual

70 ALFOplus 24GHz (North America) - Release 01.05.0x - MN.00395.E - 004
Tab.11 - Mounting Instructions
Description
Remove the cable jacket by 30mm width approximate-
ly.
Take care not to damage the copper conductor. Clean
and dry the application area.
Remove the protective film from the butyle sealing
paste.
Put the contact in position on the cable, by firmly press-
ing on the cable jacket, checking the adherence of the
butyle sealing paste. The contact is firmly positioned on
the cable jacket.
Wrap the copper mesh around the contact and outer
conductor (at least 4 revolutions).
Block the mesh terminal under the contact tooth.
Cut the exceeding mesh length.
Remove the self-agglomerating tape protective film.
Carefully wrap tight the tape around contact and cable,
following the suitable mean line.
Tape adheres remaining in position and progressively
self-agglomerates.
Connect the earthing cable.