Software Manual

168 ALFOplus 24GHz (North America) - Release 01.05.0x - MN.00395.E - 004
- Rx spurious emissions according to FCC Part 15
- AGC dynamic range from -22 dBm to Threshold @ BER=10
-6
- Accuracy of Rx level indication @ 25 C° (PC reading)±2dB in the range -22dBm ÷ Thresholds @
BER=10
-6
- Accuracy of Rx level indication over the whole
temperature range (PC reading) ±3dB in the range -50dBm ÷ Thresholds @
BER=10
-6
±4dB in the range -49dBm ÷ -22dBm
- Maximum input level for BER 10
-6
-22 dBm
- Residual BER (RBER) 10
-12
30
BER=10
-6
-69.0 -66.0 -62.5 -60.0 -56.0
BER=10
-10
-67.0 -64.0 -60.5 -58.0 -54.0
40
BER=10
-6
-68.0 -65.0 -61.5 -59.0 -54.5
BER=10
-10
-66.0 -63.0 -59.5 -57.0 -52.5
50
BER=10
-6
-67.0 -64.0 -60.5 -58.0 -53.5
BER=10
-10
-65.0 -62.0 -58.5 -56.0 -51.5
56
BER=10
-6
-66.5 -63.5 -60.0 -57.5 -53.0
BER=10
-10
-64.5 -61.5 -58.0 -55.5 -51.0