12.2.2 Configurability
The management mode of equipment affects the Ethernet Channel and on the Switch configuration (RSTP,
OAM, …). Therefore it is important to decide the optimal configuration of traffic Ethernet and management,
to avoid blocking traffic conditions.
In out of band a dedicated service channel for management does not exist, but this is forwarded to radio
side using “internal Vlan stacking” with priority7, so that traffic IP with priority 7 could affect the speed of
management traffic.
The disabling of PortA interface can cause outage of management and data traffic.
12.2.3 Address
The unit uses a single IP address associated at the management port of controller and a single "default
gateway".
12.2.4 Restore supervisioning access mode
The “RESTORE OF CPU ACCESS” command is available through Serial port (F03594 cable) via Hypertermi-
nal (115200bps,n,8,1):
Login SYSTEM
•Password SIAEMICR
•Type string: lao
This string restores the setting of port configuration:
LAN1 disable
LAN2 local access only