Software Manual
ALFOplus 24GHz (North America) - Release 01.05.0x - MN.00395.E - 004 147
Fig.104
or for Both radio
• Set Timeout_Local= 580sec and Timeout_Remote= 600sec
• Enable Remote Radio BER TEST (step a,b,c)
• Immediately, enable the Local Radio BER TEST
• Check Local status: BER,Sync Loss, Errors, Elapsed Time, events
Fig.105
Ber Test on
Local ALFOplus
RF Loop
a
b
c
Timeout = 0
Ber Test on
Ber Test on
Timeout = 600
Timeout = 580
BER TEST is traffic affetting!
ALFOplus link