Software Manual

144 ALFOplus 24GHz (North America) - Release 01.05.0x - MN.00395.E - 004
11.8.5 Alarm groups: PLUG-IN MODULE
Tab.30 - Alarm groups: PLUG-IN MODULE
11.8.6 Group alarms: RADIO
Tab.31 - Group alarms: RADIO
HW Mismatch Alarm Internal Problem
Hot Reset, Cold Reset, Factory De-
fault Reset, Substitute with spare
part.
Missing Alarm Internal Problem
Hot Reset, Cold Reset, Factory De-
fault Reset, Substitute with spare
part.
Not Responding Alarm Internal Problem
Hot Reset, Cold Reset, Factory De-
fault Reset, Substitute with spare
part.
Sw Mismatch Alarm Internal Problem
Hot Reset, Cold Reset, Factory De-
fault Reset, Substitute with spare
part.
Problem Solution
Plug-in module Status
Plug-in module has been switched
on/off
Plug-in module Mismatch
Plug-in module not managed or
missing
Substitute SFP module
Plug-in module Fail
Plug-in module not detected/not
working
Substitute SFP module
Plug-in module Loss of Signal No signal received by SFP module
Check cable connected to SFP
module
Radio Problem Solution
Link Id
Wrong LinkID. Possible interference prob-
lem.
Check remote station/LinkID
config (local and remote)
Link Telemetry Fail Radio Link down (traffic is interrupted)
Check local station/propagation/
remote station
Adaptive Modulation Re-
duced Capacity Notification
Actual Modul. profile is not the Upper
Check Link parameters/propaga-
tion status
Ber Sync Loss Alarm BER Test Fail Active one loop or disable Ber test
Invalid Frequency Alarm
Set
Frequency not permitted Change Frequency Channel
Rx Power Low Alarm
The Rx Power level is lower than the
threshold set
Reduce the Rx Power Threshold in
general preset
Tx Power Alarm Received power below the fixed threshold Tx off command active/Tx fail
UNIT Problem Solution