Software Manual
142 ALFOplus 24GHz (North America) - Release 01.05.0x - MN.00395.E - 004
In case of ACM disable the alarms sequence is the same despite of Adaptative Modulation Reduced Ca-
pacity Notification:
Fig.102
Plug-in Module Mismatch Alarm+Plug-in Module Fail Alarm+Plug-in Module Loss of
Signal Alarm+Base Band Lan 1 Loss of Signal Alarm
• SFP Module Missing/Faulty/Not Compatible in Port 1.
Fig.103
11.8.2 Alarm groups: COMMON
Tab.26 - Alarm groups: COMMON
Common Problem Solution
Ethernet Traffic Concatenation fail
on radio link
Packets loss on Radio port or ex-
cessive propag delay in one
stream
Check streams status/ODUs sta-
tus
Ethernet Compr./Fragm. Config.
Mismatch
Local and Remote have different
compr/fragm setting
Check compression and fragmen-
tation setting
IEEE 1588 PTP Configuration Mis-
match
Local 1588 setting is different
from the remote
Check 1588 configuration
IEEE 1588 PTP PPS Unlock
PPS signal in slave IDU has drift
problems
Chcek 1588 configuration or port
status
G8032 Ring: <...> Port:<...>
Alarm Status
CCM message from Ring <...> not
received from remote
Chcek VLAN, Domain and G8032
setting.
Check Ethernet connection