Software Manual
ALFOplus 24GHz (North America) - Release 01.05.0x - MN.00395.E - 004 111
Rescue connection using WLC (you don’t know IP address)
1. Assign a static IP address (see Fig.78) to PC (172.20.253.14/255.255.0.0).
ALFOplus rescue IP address: 172.20.253.13
ALFOplus rescue Subnetwork Mask: 255.255.0.0
2. Connect your PC directly to ALFOplus with a LAN cable
3. By WLC, press the arrow down near the button connect and press “Rescue connection” (see Fig.81
)
4. Type equipment user/password and follow the instructions of rescue login (see Fig.82)
5. In “Rescue connection” mode it is possible to set or recover the values for management access:
- Agent IP Address in General Info, menu Equipment Properties
- IP Address in Ethernet, menu Port Configuration
- InBand/Out of Band LAN1/LAN2 in Supervisioning, menu Port Configuration
Warning: the supervisioning configuration is applied immediately, instead IP address and Subnet-
mask requires apply store and restart.
Warning: in Rescue modality is allows only modify the menu "Port Configuration" and "Software Info
& Maint. This modality cannot be use to change Radio or Ethernet parameters.
Rescue connection using “Command Prompt” (you don’t know IP address)
1. Assign a static IP address (see Fig.78) to PC (172.20.253.14/255.255.0.0)
ALFOplus rescue IP address: 172.20.253.13
AFOplus rescue Subnetwork Mask: 255.255.0.0
2. Connect your PC directly to ALFOplus with a LAN cable
3. By command prompt, type “ping 172.20.253.13 -t” and press Enter.
4. Restart hardware ALFOplus
5. Wait till the ping reply, open Internet Explorer, type in the URL: 172.20.253.13 and press F5 until
the login menu appears
6. In rescue connection mode it is possible to set or recover the values for management access:
- Agent IP Address in General Info, menu Equipment Properties
- IP Address in Ethernet, menu Port Configuration
- InBand/Out of Band LAN1/LAN2 in Supervisioning, menu Port Configuration.
Warning: the supervisioning configuration is applied immediately, instead IP address and Subnet-
mask requires apply store and restart.
Warning: in Rescue modality is allows only modify the menu "Port Configuration" and "Software Info
& Maint. This modality cannot be use to change Radio or Ethernet parameters.
Emergency connection (you don’t know IP address)
1. Connection between PC and ALFOplus with serial console cable (F03594) in auxiliary connector
2. using Hyperterminal - serial COM at 115200bps, 8bits, none parity, 1 stop bit, no flow control and
press “Enter” button to access in the login
3. after login will be shown the radio IP address
4. type “Config” if you want to change the boot parameters (IP address, etc...)