Software Manual
110 ALFOplus 24GHz (North America) - Release 01.05.0x - MN.00395.E - 004
9.3 ALARM LED CHECK
On the rear panel of ODU unit there is a transparent plastic window to see the status of an internal LED
dedicated to show unit alarms. Further information about ALFOplus alarms can be found onto Section 5.
MAINTENANCE.
9.4 CONNECTION PROCEDURE
Connection between PC and ALFOplus can only occur if the IP address of the PC and the radio belong to
the same subnet and it can be made directly or through a switch on the LAN2 connector.
Using Subnetwork Craft Terminal (SCT) (you know IP address):
1. press button Options, a window will open; select card Connection
2. select Connect using local area network (see Fig.77
)
3. press OK and Connect
4. type the equipment IP address stored previously (Factory Default are 172.20.254.14/16 ODU L and
172.20.255.15/16 ODU H)
- Default User: SYSTEM
- Default Password: SIAEMICR
5. after connection it’s possible to modify IP address, etc.....
Using WebLCT console (WLC) (you know IP address):
1. add the IP address of radio in the LAN address book (see Fig.81
)
2. press double click over the IP address to open the browser.
Rescue connection using SCT (you don’t know IP address)
1. Assign a static IP address (see Fig.78) to PC (172.20.253.14/255.255.0.0)
ALFOplus rescue IP address: 172.20.253.13
ALFOplus rescue subnetwork mask: 255.255.0.0
2. Connect your PC directly to ALFOplus with a LAN cable
3. By SCT, connect using Local Area Network, press connect button, type equipment user/password
and press RESCUE button (see Fig.79
)
4. Follow the instructions of rescue login (see Fig.80
)
5. In “Rescue Connection” mode it is possible to set or recover the values for management access:
- Agent IP Address in General Info, menu Equipment Properties
- IP Address in Ethernet, menu Port Configuration
- InBand/Out of Band LAN1/LAN2 in Supervisioning, menu Port Configuration.
Warning: the supervisioning configuration is applied immediately, instead IP address and Subnet-
mask requires apply store and restart.
Warning: in Rescue modality is allows only modify the menu "Port Configuration" and "Software Info
& Maint. This modality cannot be use to change Radio or Ethernet parameters.