CVS-126 CVS-126 Instruction Manual Doc No. 0093132702 Document Revision History No. Doc. No / Rev. No. Date Revised Revised Content 0 0093132702-00 09/04/2008 First edition 1 0093132702-01 25/05/2008 Chapter all 2 3 4 5 6 7 8 9 10 Revision criteria for document number/version number If any contents of the document has been revised, the version number is altered on the cover sheet and corresponding chapter revised, while the other chapters remain unchanged.
Important Notice CVS-126 Important Notice • The re-use and transcription of Instruction Manual (hereafter called this manual) needs permission of our company. Our company prohibits the un-authorized re-use and transcription. • If this manual is lost or damaged, consult our dealer or our company. • The specification of our products and the content in the Instruction Manual are subject to changed without notice.
CVS-126 For Your Safe Operation For Your Safe Operation Pictorial used in this Instruction Manual This Instruction Manual uses the following pictorials. Understand the meaning of each pictorial and implement the maintenance and inspection. Symbol Meaning Mark for warning This symbol denotes that there is a risk of death or serious injury when not dealing with it correctly.
For Your Safe Operation CVS-126 Use the specified fuse. If un-specified fuse is used, it may cause a fire, smoke or damage. Whenever transmitting, be sure to submerge the transducer in water first. If transmitted without submerging the transducer, it may be damaged. Caution Item on Equipment Be careful of a high voltage inside. A high voltage, which may risk your life, is used. This high voltage remains in the circuit after you have powered off switch.
CVS-126 Contents Contents Document Revision History....................ⅰ Selection of Echo sounder mode Important Notice .....................................ⅱ and Depth mode ........................ 1-8 For Your Safe Operation ........................ⅲ Fine-adjusting the Auto Gain ..... 1-9 Contents .................................................ⅴ Adjust the gain manually. ........... 1-9 Introduction.............................................. ⅶ Easy Gain Adjustment................
Contents CVS-126 Image Swap ............................. 2-14 Stopping the alarm sound ..........2-5 Setting the alarm ........................2-6 Release the alarm. .....................2-6 Confirm the alarm state..............2-6 2.13 Preset/ WPT edit/ WPT delete of Destination.................................2-6 NAV Start. ...................................2-6 Cancel the NAV. .........................2-7 Chapter 3 How to use the system menu .3-1 3.1 Display of System Menu ............ 3-1 3.
CVS-126 Introduction Introduction The CVS-126 is a Dual frequency (50kHz/200kHz) Color LCD display echo sounder. This unit equipped with digital process displays the circumstance in the water under all conditions, matching with the high luminance 5.7 inch LCD. The main features of this unit are as follows. • With the digital reception process, the compatibility of the high resolution in a shallow depth and the noise rejection capability in a deep depth are established.
System Configuration CVS-126 System Configuration Connection Diagram CVS-126 Display unit GPS sensor GPS-20A External Navigation Equipment External water temperature meter External speaker (For speaker with amplifier) (Prepared by a user) TD: transducer * (Inner-hull, through-hull) * TD-500T-2B (Inner-hull) * TD-500T-3B (through-hull) (Dual frequency combination type 50/200kHz) Water temperature sensor / speed sensor ST-80/90/100 Requirement: Option cable (CW-840-0.
CVS-126 System Configuration CVS-126 echo sounder unit With mounting bracket and protection cover Legend To Transducer connector Standard configuration Option To POWER connector CW264-2M External power output (For GPS etc) External speaker (For speaker with amplifier) (Prepared by a user) NMEA circuit input output GPS sensor (GPS-20A) External navigation equipment, external water temperature meter Red Black - DC10.8~31.2V Option cable (CW-840-0.
Configuration of Equipment CVS-126 Configuration of Equipment Standard Equipment Configuration List No Name of item 1 Transmission-receiver display unit CVS-126 2 Protection cover C38MB12020 3 DC power cable (Complex cable) CW-264-2M With 12 connector at one end/ un-treated at the other end 4 Fuse F-7161-2A Cylinder (ø6.
CVS-126 Configuration of Equipment Essential Option No 1 Name of item Transducer Type Remark Type of transducer transducer cable (with connector at one end) Weight/ Length 9m Quantity 1 Type of transducer No Specification Frequency Material Mounting method 1 TD-500T-2B 50/200kHz Plastic Inner-hull (The inner-hull kit is needed.
Chapter 1 Basic Operation CVS-126 Chapter 1 Basic Operation 1.1 How to use the key CVS-126 Display unit 1 2 3 5 4 6 7 8 In addition, for your convenience when operating keys other than keys in the menu by the【MENU】key, the menu displayed automatically closes. No. Key Name Explanation 1 【DISP】 It switches to the high frequency or low frequency of echo sounder image, zoom and navigation menu. 2 【EVENT】 It notifies the external equipment of the present position. It presets the menu.
CVS-126 Chapter 1 Basic Operation How to remove the protection cover While widening the claws at right and left sides of protection cover, draw the protection cover towards you. Claw When removing CVS-126 Display unit: To prevent dust from entering, cap the connector at the rear of CVS-126 Display unit and the power cable with caps. Install the supplied cap to the transducer cable as shown in the figure and cap it. Caution: Do not pull the cable strongly. If you do so, it will be broken.
Chapter 1 Basic Operation CVS-126 Rainbow pattern Time mark Range Function icon Gain 1.2 Power On/Off Power on 1 Press the 【BRILL 】 key to power on. The startup menu is displayed. When started up, the memories (ROM, RAM) are automatically checked. When checking is normally finished, the menu below is displayed.
CVS-126 1.3 LCD Brilliance Adjustment Chapter 1 Basic Operation 2 Disp NAV1/ Normal (H) Normal (H) Zoom (H) Dual Freq Zoom (L) Normal (L) NAV2/ Normal (L) Adjustment of LCD Brilliance The [Lcd brill] and [Panel brill] can be switched every time when pressing the 【BRILL 】key. 1 Press the 【BRILL 】 key for a short period of time to display the menu ([Lcd brill]). 2 Rotate the 【Knob】. When “1” is selected, it is darkest. When “10” is selected, it is brightest.
Chapter 1 Basic Operation CVS-126 Dual Frequency The high frequency image can be displayed in the right half side and the low frequency image can be displayed in the left half side. Since the beam width differs depending on frequency, the school of fish and sea bottom look different. Low frequency image High frequency image Zoom (Low frequency, high frequency) A part of normal image can be zoomed.
CVS-126 Chapter 1 Basic Operation The display width of zoom is displayed in orange. (1) Bottom Normal image Zoomed range 30.0 Zoom image (2) Bottom Discrimination The display width of zoom is displayed in orange. Normal image Zoomed range 30.0 Zoom image The display width of zoom is displayed in orange. (3) Zoom Normal image Zoom start position Zoomed range 30.
Chapter 1 Basic Operation CVS-126 The display width of zoom is displayed in orange. (4) Bottom Zoom Normal image Zoomed range 30.0 Zoom image The image below the bottom is not zoomed. (5) Bottom Follow Zoom The display width of zoom is displayed in orange. Normal image Zoomed range 30.0 Zoom image Navigation Menu (NAV1, NAV2) The navigation menu can be displayed at the left side on the display. To display the information other than depth, sensors need to be connected. (See [2.
CVS-126 Chapter 1 Basic Operation Range 1.5 Switch-over of Range 5.0 10.0 50.0 80.0 100.0 150.0 300 500 The range of measured depth displayed on the display can be changed. To meet your purpose, select the range of measured depth. Set the range switching to auto range. By following automatically the bottom, the image of echo sounder in the suitable range of measured depth can be displayed. 3 Caution: By selecting the [D.range] → [Range preset], the range can be preset.
Chapter 1 Basic Operation CVS-126 image. Adjust properly the gain so that the optimum image can be always displayed. Gain select Manual Cruising Fishing 3 Press the 【MENU】 key to close the menu. When the [Cruising mode] is set, the [A : AC] is displayed at the upper side of menu. When the [Fishing mode] is set, the [A : AF] is displayed at the upper side of menu. Over-gain Fine-adjusting the Auto Gain When the [Cruising mode] or [Fishing mode] is set, the gain can be fine-adjusted.
CVS-126 Chapter 1 Basic Operation Confirm the gain state. The present set value of frequency (high frequency or low frequency) adjusted last is displayed at the upper left side of menu. Example) The high frequency gain is 8.0 → H: 8.0. H:8.0 R:M When presetting the destination, switch [NAV] → [EVENT Key set] → [Store pos]. 1 In the state that no other key is pressed, press the 【 】 key or 【 】key. 2 Move the cursor (Redline) with the 【 】 key or 【 】 key to the location to be preset as a destination.
Chapter 1 Basic Operation CVS-126 Store the image. L When you find the school of fish or tide, its location can be stored as a destination. (10 locations at maximum) H When storing the image, switch [NAV] → [EVENT Key set] → {Store pos}. 1 Press the 【EVENT】 key. The image of echo sounder presently displayed is stored and the list number of stored image is displayed. It registered in Pic list No.
CVS-126 Chapter 1 Basic Operation 1.8 Use of 【FUNC】 key L H When factory-shipped, the [Image Speed] is assigned to the 【FUNC】 key. The function settable to the 【FUNC】 key can be selected among [Image Speed], [Interference Rejection], [Color Rejection], [Noise Rejection], [Range Mode], [Shift], [Zoom Range], [Zoom Start], [Background] and [White Line]. Set the function frequently used for your convenience. How to use the 【FUNC】 】 key 1 2 Cursor (Redline) 3 4 Change the setting by rotating the 【Knob】.
Chapter 1 Basic Operation 4 CVS-126 Press the 【MENU】 key to close the menu. The icons of functions preset are displayed at the upper right side on the menu. Image Speed IR Color Rejection Noise Rejection Range Mode Shift Zoom Range Zoom Start Background Color White Line L 1.9 Operation of VRM The VRM (movable marker) shown by the green line can be moved up and down. It is convenient to measure the depth by aligning with the target such as school of fish. 1 Press the 【 】 key or 【 】 key.
CVS-126 Chapter 2 How to use the Menu Chapter 2 How to use the Menu 2.1 How to operate the menu Adjust D.range Image Alarm1 Alarm2 NAV Disp Sonar Next Display the menu. / Stop the display of menu. 1 Press the 【MENU】 key. The menu and explanation of operation are displayed. Cursor Name of menu selected Menu column Setting item column Setting value Adjust D.
Chapter 2 How to use the Menu the 【 】 key. The cursor returns to the menu column. 8 Press the 【MENU】 key to close the menu. CVS-126 having the same frequency and same firing times as those your boat has, the interference noise may be displayed. If you set the interference rejection, the interference noise can be reduced. In the order of weak → strong, the noise rejection capability becomes high. 2.2 Change of Image Speed Image of school of fish The image speed of echo sounder can be changed.
CVS-126 3 Chapter 2 How to use the Menu Change the setting of [Color Rejection]. Color Rejection 0 % 4 Setting of Fixed Shift The scope of range starting with the shift value is displayed. Press the 【MENU】 key to close the menu. 2.5 Rejection of Noise Noise Rejection The influence of noise can be reduced. Due to echo reflected from plankton and dust, the speck-like noise may appear on the entire image.
Chapter 2 How to use the Menu CVS-126 and [Bottom Follow Zoom] Zoom start 10 The zoom range of each mode is identical. 0~800 (See [1.4 Switch-over of Menu].) (setting:except ft:2.5~200,ft:10.0~650) 4 m Press the 【MENU】 to close the menu. 2.9 Setting of Background Color Zoom Range Responding to the ambient brightness, the background color of display can be changed. 1 2 3 1 2 3 Press the 【MENU】 key. Select [Display] → [Background Color]. Change the setting of [Background Color].
CVS-126 Chapter 2 How to use the Menu 2 Select [Disp] → [White Line]. 3 Change the setting of [White Line]. “1” is narrowest. “5” is widest. In the auto mode, responding to the strength of echo reflected from the bottom, the width of white line changes. [Fish alarm] issues the alarm when an echo recognized as school of fish exists in the set range.
Chapter 2 How to use the Menu Setting the alarm Adjust D.range Image Alarm1 Alarm2 NAV Disp Sonar Next Bottom alarm Upper depth Lower depth OFF 5m 50m Fish alarm Position OFF 5m Range Level Return 50m Medium CVS-126 The set state of [Water temp alarm], [Speed alarm], [Arrival alarm] and [XTE alarm] can be confirmed by the icons at the upper side of display. [XTE alarm] [Speed alarm] [Arrival alarm] [Water temp alarm] [Bottom alarm] Adjust D.
CVS-126 Chapter 2 How to use the Menu [WPT edit] list. Caution: The list No. selected is reversed in red. 4 After selecting the number, press the 【 】 key or the 【Knob】. 5 Select the [Yes] in the confirmation menu and press the 【MENU】 key. Then, the NAV starts. 4 After selecting the number, press the 【 】 key or the 【Knob】. 5 Select the character with the 【 】 key or 【 】 key. ( character: A~Z,blank,0~ 9,+,-./) 6 Move the position of characters to be reversed with the 【 】 key or 【 】key.
Chapter 2 How to use the Menu pressed, the setting is cancelled and the menu returns to the menu item. Caution: If the values of latitude and longitude are abnormal or are not entered, they cannot be preset. 7 8 After finishing the edit work, press the 【MENU】 key. Select the [Preset] in the confirmation menu and press the 【MENU】 key. Then, the edit is finished. Edit is finished Yes No CVS-126 Caution: If the 【Knob】 】 is pressed at this moment, it is canceled.
CVS-126 Chapter 2 How to use the Menu H L 5 When the echo sounder image to be stored appears, press the 【EVENT】 key. 6 When the image store is fully filled, it shows that the [Store image] is fully filled. After deleting the unwanted image, try it again. Recall the stored image. The image stored in the past can be recalled. During recalling, the image cannot be stored. 1 2 Press the 【MENU】 key. 3 Select the number of image to be recalled from the [Image recall] list.
Chapter 2 How to use the Menu CVS-126 4 Image delete No. 1 2 3 4 5 6 7 8 9 10 4 5 Comment PIC00001 PIC00002 PIC00003 PIC00004 PIC00005 PIC00006 PIC00007 PIC00008 PIC00009 5 No. Comment 1 P I C00001 2 P I C00002 P I C00003 3 6 After selecting the number, press the 【 】 key or 【Knob】 to enter. Select the comment position with the 【 】 key or 【 】 key. Image comment No. Comment 1 P I C00001 2 P I C00002 P I C00003 3 Select the [Yes] in the confirmation menu and press the 【MENU】 key.
CVS-126 Chapter 2 How to use the Menu Zoom select display1 BTM. B.D. Zoom B.Z. B.F.Z. RNG HDG BRG display2 Water temp The time required Course Wind dir. display3 display4 4 Press the 【MENU】 key to close the menu. XTE For each zoom display, refer to [1.4 Switch-over of display]. Boat speed Lat/Lon Wind speed Depth 2.16 Selection of NAV Display The information can be displayed on the NAV display (NAV 1, NAV2). Information to be displayed in 1 to 4 Wpt dist dir., Time required, Wind dir.
Chapter 2 How to use the Menu key. Caution: Every time when pressing the 【 】 key, the [Display] switches in the order of [NAV1] to [NAV4]. 6 7 Select the [NAV] by rotating the 【Knob】. Press the 【MENU】 key to close the menu. 2.17 Explanation of Sonar Switch-over of Sonar Tone The sonar can be outputted to the built-in speaker by selection. The school of fish and condition of bottom on the display of echo sounder can be confirmed by hearing the sonar. Sonar tone OFF ON 1 2 3 Press the 【MENU】 key.
CVS-126 Adjust D.range Image Alarm1 Alarm2 NAV Disp Sonar Next Chapter 2 How to use the Menu Image speed IR Color Rejection 1/1 Strong 0% Noise Rejection Clutter 0.0 5 TGV TX power Return Medium Auto 1 Select the [Display] → [A scope]. 2 To display the A scope, select the [ON]. To stop the display of A scope, select the [OFF]. Change the display color of echo sounder image The [Monochrome], [8 color], [16 color] and [64 color] can be selected. 1 2 Select the [Adjust] → [TX power].
Chapter 2 How to use the Menu Adjust D.range Image Alarm1 Alarm2 NAV Disp Sonar Next 1 2 Disp width Image swap NAV 1 NAV 2 Return CVS-126 Center A B 2 4 Select the [Disp] → [Disp. width]. Select the width of image. Image Swap The images of echo sounder at the right and left sides can be swapped. 1 2 Select the [Display] → [Image swap]. Select the swap state.
Chapter 3 How to use the system menu CVS-126 Chapter 3 How to use the system menu 3.1 Display of System Menu After powering on, besides the menu displayed first with the 【MENU】 key, the system menu, of which setting is not frequently changed, is provided. [In out],[Correct],[System],[Setting],[Maintain] Display the system menu 1 Press the 【MENU】 key. 2 Select the [Next]. Adjust D.range Image Alarm1 Alarm2 NAV Disp Sonar Next 3.2 Setting of External In/Out Set the setting related to the input/output.
CVS-126 Chapter 3 How to use the system menu NMEA Monitor Draft Set The external input data can be displayed. The tolerance of depth can be corrected. To return to the original menu, press the 【MENU】 key. Set the depth from the sea level to the set depth of your transceiver/receiver. Normally set draft value of your boat.(setting: expect ft:-10.0~ 10.0,ft:-30.0~30.0) NMEA Output Data The output of NMEA sentence can be set to ON/OFF. Sonic Speed 1 Select the sentence name.
Chapter 3 How to use the system menu CVS-126 Simple Menu Depth Unit Set the simple menu display. It switches the unit of depth to fm, l.fm and ft. The items displayed in the menu are limited only to the setting items of minimum requirement. When making the setting change fewer, it is convenient. Temperature Unit It switches the unit of temperature to °C, °F. Operation Guide When displaying the menu, it sets whether or not the operation guide is displayed at the lower part on the display.
CVS-126 Chapter 3 How to use the system menu Initialize It returns all the settings in the menu to the factory settings. However, the memorized data of display remains unchanged. Caution: It returns to the factory settings and the power is automatically shut down. System Check It is used for diagnostic test. (See [4.5 Diagnostic Test ].) All WPTs deletes All WPT lists can be deleted. All stored image deletes All stored image lists can be deleted.
Chapter 4 Maintenance and Inspection CVS-126 Chapter 4 Maintenance and Inspection 4.1 Inspection The daily maintenance and inspection extends the life of equipment. To always keep the equipment in the best condition, implement periodically the inspection shown in the table below. Item Content of Inspection Connector at the rear of CVS-126 Display unit Check the looseness. Wiring of cables Check the wiring of cables connecting the equipment and the damage of cable.
CVS-126 Chapter 4 Maintenance and Inspection 4.4 If you suspect a trouble Symptom Trouble cause Countermeasure Even if the power is powered on, nothing is displayed. • Blown fuse. • The power voltage is out of specification (10.8 to 31.2 VDC). • Poor connection between power cable and battery. • Exchange a fuse.(See [4.3 Fuse Replacement]) • Use a proper power as per specification. • Confirm a connection between the power cable and the battery. The unit starts up.
Chapter 4 Maintenance and Inspection CVS-126 4.5 Diagnostic Test Perform the operation diagnosis. When checking the operation diagnosis of panel key, the state of sensor inside and the version of software, it is using. Return to the normal menu. Press the 【MENU】 key for more than 3 seconds. ① ROM RAM NM EA OK VOLT T EMP S PEED NG ② GAIN ③ KM-E67 Ver1.00 20080408 FishSnd ver01.00 Jan 23 2008 09:18:54 Ipl ver01.00 Jan 24 2008 15:21:33 SimData ver01.00 Jan 24 2008 15:21:33 TOP.
Chapter 5 Installation CVS-126 Chapter 5 Installation 5.1 Item of Caution on Installation To exercise fully the performance of echo sounder, the installation of CVS-126 must be performed by an engineer who is officially authorized by our company. The installation work includes the following content.
CVS-126 Chapter 5 Installation The equipment is not waterproofed. Avoid excessively damp place. Do not install the equipment in place suffering from excessive water-drops. Otherwise, the inside of display window mists over or corrosion may occur inside. Laying and Connection of Cable (1) Keep the transducer and power cable as far away from the cables of other electronic equipment as possible.
Chapter 5 Installation CVS-126 Desk-top Installation (1) Loosen the knob bolt fixing CVS-126 Display unit to the mounting bracket, push the unit to the left side and pull the unit upward. CVS-126 Display unit Knob bolt Turn two turns the knob bolt to loosen it and pull the unit upward. Fixing screw 4 (2) Place the removed unit to a safe and flat place.
CVS-126 Chapter 5 Installation Threading hole 160 16 R30 Fixing screw 4mm Not supplied 4 pieces Front frame Figure 5.3 Flush-mount Installation Figure 5.
Chapter 5 Installation CVS-126 5.3 Installation of Transducer The standard installation of this echo sounder is shown in figure 5.5. Figure 5.5 Installation of Transducer In case of Inner-Hull Using the optional inner-hull kit (MFB-04), install the transducer to the inner side of ship’s bottom. Caution on installation Figure 5.6 Inner-Hull Installation (1) Select the location where no bubble is generated during navigation. (2) Select the relatively thin location of ship’s bottom.
CVS-126 Chapter 5 Installation In case of through hull Install the transducer directly to the ship’s bottom Installation Procedure (1) Select the installing location. (2) Remove the fixing nut and one piece of rubber packing. (3) If the slope of ship’s bottom is greater than 5°, make a wooden base to fit to the slope of ship’s bottom. To reduce the water resistance, cut the bow direction tip of wooden base at the outer side of ship’s bottom in the triangle shape.
Chapter 5 Installation CVS-126 5.4 Wiring Connection of Cable to CVS-126 Display unit Connect the power cable and transducer to the connectors of CVS-126 Display unit. POWER Power input 10.8~31.
CVS-126 Chapter 5 Installation Connection of Power Cable and Transducer Connect the power cable to the [POWER] connector and the transducer to the [TD] at the rear of CVS-126 Display unit connector. Connection of DC power cable (CW-264-2M) 3.5 stereo jack To [POWER] connector DC+ (Red) DC- (Black) Caution: Wind the insulation tape around the un-used lead wire for core-wires not to contact each other. Connection of transducer To [TD] connector Grounding • Use heavy gauge cable for grounding wire.
Chapter 5 Installation CVS-126 Connection with Speed Sensor or Water Temperature Sensor (Option) When installing the optional speed sensor or water temperature sensor, connect to the [TD] connector together with the transducer via the transducer cable (Type: CW-840-0.3M). For wiring, see the figure below. After soldering, implement the waterproof and insulation treatment on the connected part with the self-melting tape.
CVS-126 Chapter 5 Installation Connection of External Speaker (Prepared by a customer) The ø3.5 stereo jack is provided to the power cable. If you connect the speaker with the amplifier to the external, you can clearly hear the sonar sound. Adjust the volume of speaker with the amplifier equipped to the speaker 3.5 stereo jack 5.5 Serial Data Input Data The sentences of GGA, GLL,HDT, MTV, MWV, RMC, VHW, VTG and ZDA can be received. The type of NMEA0183 Ver.1.5, Ver.2.0 and Ver.3.0 can be inputted.
Chapter 6 Table Attached CVS-126 Chapter 6 Table Attached 6.1 Menu List The factory set value is shown by the bold and underline.
CVS-126 Chapter 6 Table Attached ,Homing Inner-hull (-10~10:0) GLL HDT MWV RMC Other KODEN GPS All WPTs:DLT All IMG DT:DLT 0093132702-01 6-2
Chapter 6 Table Attached CVS-126 6.2 Specification Serial Data Indicator Overall Item Model Transmission Frequency Transmission Method Transmission Power Condition Environment Single or alternate 600W Transmission Firing Times Transmission Pulse Width Minimal Reception Gain Display Display Mode Zoom Mode 5.
CVS-126 Chapter 6 Table Attached 6.
Chapter 6 Table Attached 6-5 CVS-126 0093132702-01
11001 Roosevelt Blvd., Suite 800 St. Petersburg, FL 33716 Tel: 727-576-5734 Fax: 727-576-5547 Website: www.kodenamerica.