Datasheet
Product Specifications
www.shuttle.eu
Shuttle Computer Handels GmbH
Fritz-Strassmann-Str. 5
25337 Elmshorn | Germany
Tel. +49 (0) 4121-47 68 60
Fax +49 (0) 4121-47 69 00
sales@shuttle.eu
Pa
g
e 7 10 October 2014
© 2014 by Shuttle Computer Handels GmbH (Germany). All information subject to change without notice. Pictures for illustration purposes only.
Front Panel
Power on after Power fail
The BIOS setup provides a "Power-On after Power Fail" function that can
be found under "Power Management Configuration". As the name
indicates, this function determines the PC's behaviour after power
failure: (1) unconditional power on, (2) restore former status or (3) keep
system turned off. As a matter of the nature of this function, it may fail
after short power failures. This is why the DS87 also comes with a
hardware-based solution. By removing Jumper 4 (see image) the
system will start unconditionally once power is applied.
DS81 DS87
Chipset H81 H87
Displays
supported
2 3
DS81 versus DS87
DS81 and DS87 distinguish themselves through their chipset. While DS81
supports dual independend displays the DS87 even supports three
displays simultaneously.
Shuttle Slim PC Barebone DS87 – Required Components
The following components need to be added to make it a fully-configured Mini PC
2.5” SATA hard disk
or Solid State Disk (SSD)
(max. 12.7 mm height)
Up to two DDR3-1333/1600
SO-DIMM memory modules
max. 8GB each
Windows / Linux
Operating System
LGA1150 processor
TDP max. 65W
Core i7 / i5 / i3, Pentium
or Celeron
Optional:
WLAN-Accessory WLN-S
Optional:
mSATA SSD storage