Troubleshooting guide

Modular Processors
SHURE
P4800 System Processor Software Guide Page 75 of 108
Parameter Window Features
Import
Click this button to import ASCII files from either Smaart or TEF. When the [Open File]
window appears, select the file you wish to import. The data from the imported file will
be displayed in the Response Graph. When a TEF TDS file is imported, the average
magnitude value is plotted at 0 dB and all other magnitude values are biased accordingly. By default,
Smaart transfer function files are not offset. Magnitudes are centered around the 0 dB axis, just as
they are in Smaart.
Refresh
Click this button to re-import the last imported file. If you take a new measurement in
Smaart or TEF and save it with the same file name, overwriting the previous file, you
can click the [Refresh] button to import the new measurement without having to go through the open
file dialog.
Note: The [Refresh] button DOES NOT change the bias of the original file. If the average magnitude
value of a TEF TDS file changes, the refreshed display will still be biased around the original average
value. Also, any offset you add to the file using the [Offset] text box will not change when you click on
[Refresh].
Show
Click on this button to show or hide the imported file display. The [Show] button is lighted
in green when a file is displayed.
Offset
This indicates the amount by which the display is offset from the actual amplitude values
contained in the ASCII file. By default, a TEF TDS measurement will be offset by its
average amplitude to center it around the 0 dB axis in the Response Graph
.
Invert
Click on this box to invert the displayed data around the x-axis. You may then use the
inverted display as a visual guide for EQ parameters. [Invert] is selected by default.
Help
Click on this button to access on-line help with importing Smaart and TEF ASCII files.