Troubleshooting guide

Modular Processors
SHURE
P4800 System Processor Software Guide Page 55 of 108
Distance
Use this control to specify the delay by distance. The range of values
varies, depending on the maximum delay time, but the default is always
zero. Select the appropriate unit of measure with the radio buttons to the
right of the control. When English units are selected, you can choose between inches or feet. When
Metric units are selected, distance is indicated in meters. The default value is inches.
Air Temperature
Use this control when you are setting the delay by
distance, since the speed of sound is affected by air
temperature. The range of values is from -13°F to 122°F, or -25°C to 50°C. When English units are
selected, air temperature is indicated in Fahrenheit. When Metric units are selected, air temperature is
indicated in Celsius. The default value is Fahrenheit.
Bypass
Click to pass signal through without the effect of the processor. When bypass is active, the button
appears lighted in red. The default setting is inactive.
Bypass active
Bypass inactive
Clear
Click this button to reset the processor to its system default settings.