Owner's Manual
Permanent Installation
Mount the microphone using one of the following methods.
-~·
Flange
1.
Drill a 22 mm (7/8 in.) diameter hole in the
desired
location.
2.
Trace and drill three starter holes for the
supplied screws using the flange
as
a template.
3.
Insert the preamplifier through the mounting
flange.
4.
Slip the mounting flange retaining ring over the
bottom of the
preamplifier and slide it up until it
is
flush to the bottom of the flange. Then press
the ring
firmly into place.
5.
Secure the flange to the mounting surface with
three screws.
Shock Mount
1.
Drill a 44mm(1-3/4 in.) diameter hole
in
desired mounting surface.
2.
Mark and drill starter holes for screws,
using shock mount
as
a template.
3.
Secure shock mount to mounting surface
with screws.
4.
Thread the supplied adapter onto the
MX400SE microphphone before inserting
it into the shock mount.
Specifications Certifications
Cartridge Type
Electret Condenser
Frequency Response
50-17000
Hz
Polar Pattern
MX412/C, MX418/C
MX412/S, MX418/S
Output
Impedance
1800
Output
Configuration
Active Balanced
Sensitivity
@ 1 kHz, open circuit voltage
Cardioid
Supercardioid
1
Pa:94
dB
SPL
MaximumSPL
1 kHz at
1%
THO,
1 kO load
Cardioid
Supercardioid
Equivalent
Output
Noise
A-weighted
Cardioid
Supercardioid
Cardioid
Supercardioid
-35
dBV/Pa(18 mV)
-34
dBV/Pa(21 mV)
124dB
123 dB
28dB
SPL
27 dB SPL
Signal-to-Noise Ratio
Ref. 94
dB
SPl
at 1 kHz
Cardioid
Supercardioid
Dynamic Range
1
kO
load, @ 1 kHz
96 dB
Common
Mode
Rejection
10Hz
to
100kHz
45
dB, minimum
Preamplifier
Output
Clipping
Level
at
1%
THO
--6
dBV (0.5
V)
Polarity
Positive sound pressure on diaphragm produces positive
voltage
on pin
2 relative to pin 3 of output XLR connector
Mute Switch
MX412S/MX418S
-50
dBminimum
Environmental
Conditions
Operating Temperature
Storage Temperature
Relative Humidity
Power Requirements
11-52 V
DC, 2.0
rnA
-18-57"C
(0-135°F)
-29-74°C
(-20-165°F)
0-95%
Meets essential requirements of all applicable
European Directives.
Eligible
forCE
marking.
The CE
Declaration of Conformity can be obtained
from
Shure Incorporated
or
any of its European
representatives. For contact information
please visit
www.shure.com
The CE
Declaration of Conformity can be obtained
from: www.shure.com/europe/compliance
Authorized European representative·
Shure Europe GmbH
Headquarters Europe,
Middle East
& Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str.
12
75031
Eppingen, Germany
Phone: 49-7262-92 49 0
Fax: 49-7262-92 49
11
4