Model FP33 User Guide STEREO ENG MIXER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ©2005, Shure Incorporated 27B8500 (Rev. 3) Printed in U.S.A.
TABLE OF CONTENTS ENGLISH ........................................... ......... INPUT PANEL CONNECTORS AND CONTROLS (FIGURE 2) . . . . . . . . OUTPUT PANEL CONNECTORS AND CONTROLS (FIGURE 3) . . . . . . INTERNAL SWITCHES AND CONTROLS (FIGURE 4) . . . . . . . . . . . . . INTERNAL SWITCHES AND CONTROLS (CONT.) . . . . . . . . . . . . . . . POWERING THE FP33 MIXER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BATTERY LIFE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ENGLISH ENGLISH x Precision, conductive plastic, sealed rotary input potentiometers x Bi-color LED limiter and peak indicator for each output x Two linkable output peak limiters with adjustable thresholds and release times x Slate microphone and slate tone with selectable functions x Isolated two-way talk-back using Monitor In and modified Slate Mic/Tape Out jack x High tolerance 3.
ENGLISH ENGLISH 2 1 5 4 3 1 kHz 6 7 8 FP33 LINK PEAK/LIM L R L PAN R L PAN BATT R PAN/BAL 7 3 7 3 7 -20 -2 -10-7-5 -3 0 R 10 1 11 0 10 2 0 10 0 VU 12 -20-10-7- -3 5 +15 MASTER dB 3 13 ON +3 +5 L+R 0 +3 +5 R ST L LIM 0 0 SLATE 10 L VU MIC L 3 9 R PEAK/LIM MON 14 15 16 17 18 19 Figure 1 FRONT PANEL CONTROLS AND INDICATORS (Figure 1) 1. Pan Control: Adjusts the amount of input signal sent to the Left and Right outputs.
ENGLISH 11. 12. 13. 14. 15. ENGLISH DIP Switches and Limiter Threshold Adjustment for instructions. 16. Left/Right Channel Output Level Meters: 0 VU is preset at a +4 dBm output level. This may be recalibrated for each meter by an internal trim potentiometer. See the VU Meter Adjustment paragraph for instructions. Note: Mechanical meters are used because LCD meters do not operate properly in cold weather; fluorescent meters drain batteries too quickly; and LED meters are difficult to see in sunlight.
ENGLISH ENGLISH 1 IN 1 MIC 1 LINE MIC 2 LINE MIC 3 LINE 2 Figure 2 INPUT PANEL CONNECTORS AND CONTROLS (Figure 2) 1. Channel Inputs: The three female XLR inputs are transformer balanced for superior rejection of hum, RFI, and other interference. Each input can provide 48 V or 12 V phantom power (for condenser microphones); 12 V T (A-B) power (for condenser microphones); or no power (for dynamic microphones). See the Internal Switches and Controls section. 2.
(1*/,6+ (1*/,6+ ,17(51$/ 6:,7&+(6 $1' &21752/6 )LJXUH )XVH DQG 6SDUH )XVH 'HVLJQHG WR SURWHFW WKH )3 IURP GDPDJH WKDW PD\ UHVXOW IURP XVLQJ D FRPPRQ H[ WHUQDO GF SRZHU VXSSO\ ZLWK RWKHU HOHFWURQLF GHYLFHV &DXWLRQ 'DPDJH PD\ UHVXOW ZKHQ XVLQJ D FRPPRQ H[WHUQDO GF SRZHU VXSSO\ ZLWK RWKHU HOHFWURQLF GHYLFHV WKDW DUH ´SRVLWLYH JURXQG µ 6HSDUDWH SRZHU VXSSOLHV DUH UHFRPPHQGHG %DWWHU\ &RPSDUWPHQW +ROGV WZR 9 DONDOLQH EDWWHU LHV 7ZR IUHVK EDWWHULHV ZLOO SRZHU WKH XQLW IRU DERXW HLJKW KRXUV
ENGLISH ENGLISH INTERNAL SWITCHES AND CONTROLS (Cont.) Note: Bold type indicates the Factory setting. 1 DIP SWITCH LIM LINK POSITION ON 2 LIM RELEASE R OFF SHORT LONG 3 LIM RELEASE L 4 MON DEFEAT R SHORT LONG 5 MON DEFEAT L FUNCTION Left and Right limiters act in tandem. If limiter thresholds are set differently, limiter action is determined by the lower threshold setting. Left and Right limiters act independently. Right limiter release time constant is 0.1 second. Use for speech.
(1*/,6+ (1*/,6+ 0,;(5 6(783 23(5$7,21 3UHSDUH WKH )3 VWHUHR PL[HU IRU RSHUDWLRQ DV IROORZV )RU LQWHUQDO EDWWHU\ RSHUDWLRQ OLIW WKH ODWFK RQ WKH WRS SDQHO DQG RSHQ WKH EDWWHU\ FRPSDUWPHQW ,QVWDOO WZR 9 DONDOLQH EDWWHULHV PDNLQJ VXUH WKH SRODULW\ ² LV FRU UHFW 6HOHFW WKH SURSHU PLFURSKRQH SRZHULQJ IRU HDFK LQ SXW YLD WKH VOLGH VZLWFKHV &ORVH WKH FRPSDUWPHQW GRRU DQG VHFXUH WKH ODWFK )RU H[WHUQDO SRZHU RSHUDWLRQ SOXJ D WR 9GF VRXUFH LQWR WKH ([WHUQDO 3RZHU MDFN RQ WKH ULJKW
ENGLISH ENGLISH 3. Slide the Limiter switch to the Off (down) position. 4. Adjust the Left Master gain control until the ac voltmeter reading is at the desired peak output level. 5. Open the battery compartment and turn the Peak LED L trim pot completely clockwise. 6. Slowly adjust the trim pot counterclockwise until the left Peak/Lim LED first illuminates red. 7. Repeat the above procedure for the right Peak/Lim LED, using the Peak LED R trim pot.
ENGLISH ENGLISH C in PF= (85/frequency) - .33 Example for 200 Hz corner frequency 85/200 = .43 .43-.33 = .1 PF Decreasing Tape Out Level to Mic Level 1. Locate R1112 and X511 (the top side of the bottom PC board, by the L Out XLR connector). 2. Locate R1114 and X510 (the bottom side of the bottom PC board, by the Tape Out jack). 3. Remove R1112 and R1114. 4. Solder a jumper through the holes at X511. 5. Solder a jumper through the holes at X510. For a 200 Hz corner frequency, use a 0.1 PF capacitor. 2.
ENGLISH ENGLISH Overload and Shorting Shorted outputs, even for prolonged periods, cause no damage. Microphone inputs of up to 3 Vrms cause no damage. The Line and monitor inputs can withstand signals of up to 30 Vrms. Input Channel Bi-Color LEDs Green: Signal presence; visual indication of mix level. Red: 6 dB below clipping level. Output Peak/Limiter Bi-Color LEDs Green: Output being limited by 1 dB or more. Red: Output peak threshold reached; factory set at +17 dBm; user adjustable from 0 to 17 dBm.
ENGLISH ENGLISH nications. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
SHURE Incorporated http://www.shure.com United States, Canada, Latin America, Caribbean: 5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A. Phone: 847-600-2000 U.S.