User's Manual
Table Of Contents
Shure Incorporated
11/13
•
•
Specifications
Note:
All specification values are based on using a typical bodypack with 5 V bias input or the RPM400MTQG preamplifier.
When using the RPM400LEMO amplifier, refer to the RPM400LEMO specifications.
All specifications measured with a 48 Vdc phantom power supply. The microphone operates at lower voltages, but with
slightly decreased headroom and sensitivity.
Microphone Capsule
MEMS
Polar Pattern
Omnidirectional
Frequency Response
20 Hz to 20 kHz
Sensitivity
-42.5dBV at 1 kHz
Self-Noise, A-Weighted, Equivalent Acoustical
31dBSPLA
Signal-To-Noise Ratio
63.0dB
Maximum SPL
132.0dBSPL,1 kHz at 1% THD, typical
Dynamic Range
101.0dB typical
Microphone Current Draw
220µA,maximum
Bias Voltage
Recommended Operating Voltage
5VDC, 2.6VDC minimum
Housing
Molded ABS
Polarity
MTQG
Positive pressure on diaphragm produces positive voltage
on pin 3 with respect to pin 1
[1]
[2]