User's Manual
Shure Incorporated
4/8
Load Impedance
Maximum SPL capability, output clipping level, and dynamic range vary with the input load impedance of the pre-
amplifier to which the microphone is connected. Shure recommends a minimum input load impedance of 1000
Ohms. Most modern microphone preamplifiers meet this requirement. Higher impedance results in better perfor-
mance for these specifications.
Power Requirements
This microphone requires phantom power and performs best with a 48 Vdc supply (IEC-61938). However, it will
operate with slightly decreased headroom and sensitivity with supplies as low as 11 Vdc.
Most modern mixers provide phantom power. You must use a balanced microphone cable: XLR-to-XLR.
Specifications
Type
Electret Condenser
Frequency Response
20 to 20,000 Hz
Polar Pattern
Cardioid
Output Impedance
at 1kHz
179 Ω
Sensitivity
at 1kHz, open circuit voltage, typical
-48.0 dBV/Pa (4.0 mV)
Maximum SPL
1 kHz at 1% THD
2500 Ω load 150.5 dB
1000 Ω load 144.0 dB
Signal-To-Noise Ratio
64 dB
[1]
[2]
[3]