TABLE 7·1. CUSTOMER CUT/ADD TRACE OPTIONS
TRACE
SHIPPED FROM FACTORY
DESIGNATOR
DESCRIPTION
OPEN
SHORT
U9
TERMINATIONS
FOR
MULTIPLEXED INPUTS
PLUGGED
SI
INTERNAL WRITE CURRENT SWITCH
PLUGGED
SE
EXTERNAL WRITE CURRENT SWITCH
X
TR
TRUE READY OUTPUT
PLUGGED
RTR
RADIAL TRUE READYt X
2S
TWO-SIDED STATUS OUTPUT***
X
DC
DISK CHANGE OPTION
X
S1
SIDE SELECT OPTION USING DIRECTION SELECT***
X
S2
SIDE SELECT INPUT* * * PLUGGED
S3
SIDE
SELECT OPTION USING DRIVE SELECT* * *
X
1 B,2B,3B,4B
SIDE SELECT OPTION USING DRIVE SELECT***
X
D
ALTERNATE
INPUT-IN
USE
X
MS
MOTOR
ON
FROM DRIVE SELECT* PLUGGED
MO
ALTERNATE INPUT-MOTOR
ON*
X
MMO
ALTERNATE INPUT-MULTIPLEXED MOTOR
ON*t
X
MD
MOTOR OFF DELAY
X
R
READY OUTPUT
X
RR
RADIAL READY
X
SR
STANDARD READYt
PLUGGED
MT
MODIFIED TRUE READYt
(OUTPUTS TRUE READY ON
PIN
22)
X
DS1
DRIVE SELECT 1 INPUT
PLUGGED
DS2,3,4
DRIVE SELECT 2,3,4 INPUT
X
Y DOOR LOCK/ACTIVITY LIGHT ACTIVATED FROM MOTOR
ONt
PLUGGED
z
DOOR LOCK/ACTIVITY LIGHT ACTIVATED FROM DRIVE SELECTt
X
PD
STEPPER POWER DOWN
X
WP
INHIBIT WRITE WHEN WRITE PROTECTED
X
NP
ALLOW WRITE WHEN WRITE PROTECTED
X
TS
DATA SEPARATION OPTION SELECT**
X
*MOTOR ON is
the
complement
of
HEAD LOAD on the SA801 and SA851
disk
drives. The
only
difference
in
the
operation
of
MOTOR
ON
compared
with
HEAD LOAD
is·
that MOTOR
ON
requires a 165 ms
minimum
delay (or
TRUE READY
must
be
monitored) before
RIW
activity
is begun. HEAD LOAD on the SA801 and
SA851
requires 35
ms
or
50
ms
minimum
delay.
* *The
SA81
0/860
offers
an
optional data separator
which
properly separates data and
clock
bits
thmugh
the soft-
sectored IBM standard format and address mark area. Trace
"TS"
offers
the optional separator.
* * * Applies
to
SA860 only.
tAvailable
on PCB
PIN
25249 only.