User`s manual
Installation & User’s Manual SL NITRO 510 LED STROBE Luminaire
8 INSTALLATION AND SET UP
Sh wline
2. Connecting Power
Units can be powered in one of two ways:
• Direct connection to a AC power source using an AC input cable. For wiring of AC input connector, refer to "Con-
necting SL NITRO 510 LED STROBE Luminaires to AC Power" on page 8.
• Connection from the AC output of another SL NITRO 510 LED STROBE Luminaire. When using this method, it 
is very important not to connect any other type of equipment device. 
WARNING! Only connect other SL NITRO 510 LED STROBE Luminaires to the AC Output (Thru) connector of a 
SL NITRO 510 LED STROBE Luminaire.
Connecting SL NITRO 510 LED STROBE Luminaires to AC Power
If the unit is supplied with an AC input cable without an input connector installed. The input connector is a user-
supplied accessory.
Table 2 on page 8 describes how to connect power to your SL NITRO 510 LED STROBE Luminaire. Field wiring of
the SL NITRO 510 LED STROBE Luminaire is straight forward. A total of 3 wires/conductors is supplied from the
unit. The following wiring scheme is used:
Table 2: SL NITRO 510 LED STROBE Luminaire (IP20 Rated Models) AC Input Connections
Figure 4: SL NITRO 510 LED STROBE Luminaire AC Input & Output Connections
Wire Color Purpose
Brown Main / Line (100 to 240VAC)
Blue Neutral
Green/Yellow Ground (Earth)
AC Input
AC Output
Neutral
Main /
Ground / Earth
Line
AC Connector
(on side of unit)
AC Input Connector (on Unit)
Neutral
Main /
Ground / Earth
Line
AC Connector
(on side of unit)
AC Output Connector (on Unit)
Back of Fixture