Installation guide

252 Planning and Installation Guide ShoreTel 14.2
Site Requirements and Preparation Racks and Cabling
12
Maintenance Cabling
ShoreTel voice switches support a maintenance port for connection terminal using a standard, straight-
through DB-9 female connector. This maintenance port is typically used only when assigning
networking parameters if DHCP or BOOTP is not being used.
Racks and Cabling
General Cabling Overview
The diagram in Figure 43 highlights the key components with respect to cabling for your voice network.
Figure 43: Cabling Overview
Starting from the lower left in this diagram, the telephone cabling is organized as follows:
A telephone jack (RJ-11) is provided for each telephone.
Telephone cabling (Category 3 or better) is terminated on the telephone jack and runs back to the
equipment room to a modular connector (RJ-21X) on a telephone patch panel.
The telephone patch panel provides a flexible cable management solution for the telephone
cabling. The patch panel has RJ-21X connections for the telephone cabling and RJ-11
connections on the front.
Patch cords are connected from the telephone patch panel (RJ-11) to the voice switch patch panel
(RJ-11).