Installation guide
IP8000 Conference Phone Application Note—Page 13
SIP Configuration
Navigate to the Preferences/SIP/Server section of the menu as shown in Figure 21 and apply the following settings:
Set the SIP user name to match one of the previously dened Off System Extension range in the SIP trunk group. This will 1.
also be the number that sent for 911 calls, use caution when dening this value if you plan on initiating 911 calls from the
IP8000 phone.
Set the SIP Proxy setting to Disabled.2.
Set the SIP Registrar setting to Enabled.3.
Set the registrar host name to the IP address of the ShoreTel switch that the conference phone will register with.4.
Set the registrar port setting to 5060.5.
Click on the “Save Changes” button to apply these settings.6.
Upon successful registration, the screen will show “Registrar Status: Registered”.
If this message does not appear, review the settings on both the ShoreTel switch and IP8000 conference phone respectively.
Figure 21 – SIP Conguration Screen