Specifications
ShoreTel Voice Switches Accessing ShoreTel Voice Switch CLI on the SoftSwitch
3
ShoreTel 14 Maintenance Guide 67
After you have set your IP address and boot options, enter ? to return to the main menu. You must
reboot the switch for the new setting to take effect.
Accessing ShoreTel Voice Switch CLI on the SoftSwitch
To run ShoreTel Voice Switch CLI diagnostics on the SoftSwitch, you must create a Telnet session.
ShoreTel Voice Switch CLI commands are listed in VxWorks® Command Line Interface on page 75.
1. Create the following DWORD entry in
HKEY_LOCAL_MACHINE\Software\Shoreline Teleworks\SoftSwitch
or, if you are using a 64-bit server, create the DWORD entry in
HKEY_LOCAL_MACHINE\Software\Wow6432Node\Shoreline
Teleworks\SoftSwitch:
or, if you are using a 64-bit server, create the DWORD entry in
HKEY_LOCAL_MACHINE\Software\Wow6432Node\Shoreline
Teleworks\SoftSwitch:
TelnetEnabled
2. Set the value to 1.
3. Open a Command Prompt (DOS) window and type:
telnet localhost 2323
5 Change boot method
6 Enable/disable DHCP Change boot method
7 Change network speed and duplex mode Enable/disable DHCP
8 Change network speed and duplex mode
D Set/change domain name
P Set/change primary DNS IP address Set/change primary DNS IP address
S Set/change secondary DNS IP address Set/change secondary DNS IP address
T Set/change network time server IP
address
* Display current configuration.
?Help
Note
All the information that is displayed in the session will also appear in the SoftSwitch log file.
Table 6: Boot and IP Configuration Options
Command Switch Description Voicemail-Enabled Switch Description