Specifications

C.) Contents of Interface
FUNCTIONS DISPLAY CONTENTS
Output Contents 81.dA. 1 Counting quantity data output
81.dA. 2 Weighing data output
81.dA. 3 Average Piece Weight data output
81.dA. 4 Count, Weight, APW data output
81.dA. 5 Count, Weight, Tare weight data output
Output Control 82.o.c. 0 No output
82.o.c. 1 Constant serial output
82.o.c. 2 Constant serial output when stabilized.
*82.o.c. 3
Output by pressing PRINT key.
82.o.c. 4
Automatic output with a load.
82.o.c. 5
One output when stabilized.
- No output with unstable data.
82.o.c. 6
One output when stabilized.
- Constant output with unstable data.
82.o.c. 7
One output by pressing * key but after
stabilized.
Baud Rate
*83.b.L. 1
1200 bps.
83.b.L. 2 2400 bps.
83.b.L. 3 4800 bps.
Parity Bit
*84.P A. 0 No parity bit
84.P A. 1 Odd parity check
84.P A. 2 Even parity check
* mark shows the status set at the shipping time.
18