User Manual

95
8.9 Indicating MV, Remaining Time (Program Control)
In Fixed value control and Program control, MV and remaining time are indicated.
To indicate MV, press and hold the key for approx. 3 seconds in PV/SV Display.
The unit enters Monitor mode, and indicates MV.
While MV is indicating, the decimal point flashes.
While in Standby (Program control waiting) mode of Program control, the unit cannot move to Monitor
mode.
In Monitor mode, the following contents are switched every time the key is pressed.
Model
Indicated Contents
BCS2
Fixed value control
Indicates MV, Set value memory number (in that order).
Program control
Indicates MV, Remaining time, Step number (in that order).
BCR2, BCD2
Fixed value control
Indicates only MV. (*)
Program control
Indicates MV, Remaining time (in that order). (*)
(*) For the BCR2, BCD2, Set value memory number (Fixed value control) and step number (Program control) are indicated in the
MEMO/STEP Display.
Indicating MV, Remaining time
Power ON
RUN mode
PV/SV Display
(3 sec)
Monitor mode
Indicates MV. (e.g.) MV: 7.2% (Decimal point flashes.)
Remaining time (Program control RUN)
(e.g.) Remaining time 0:30
Step number (Program control RUN) (BCS2)
(e.g.) Step 1
Set value memory number (Fixed value control) (BCS2)
(e.g.) Set value memory number 2
RUN mode
PV/SV Display