1.2 How to Read the Model Label
The model label is attached to the left side of the case.
BCS2 BCR2, BCD2
(e.g.) BCS2R00-12 (e.g.) BCD2R00-12
(Fig. 1.2-1) (Fig. 1.2-2)
No.
Description
Example
(1)
Terminal arrangement
BCS2R00-12, BCD2R00-12 (*1)
(2)
Model
BCS2R00-12, BCD2R00-12
(3)
Option
EV2 (Event output EV2)
C5W(100A) [Serial communication + Heater burnout
alarm (100 A)] (*2)
(4)
Input
MULTI-RANGE (Multi-range input)
(5)
Control output, Event output
O1: 3 A 250 V AC (Control output OUT1)
EV1: 3 A 250 V AC (Event output EV1)
EV2: 3 A 250 V AC (Event output EV2)
(6)
Power supply voltage,
Power consumption
100 to 240 V AC 50/60 Hz,
11 VA
(7)
Serial number
No. 145F05000
(*1) Terminal arrangement diagram differs depending on the model.
(*2) For Heater burnout alarm output (C5W, EIW, W options), CT rated current is entered in bracket ( ).