User Manual

7
1. Model
1.1 Model
B C 2
-
Size
BCS2
48 x 48 x 68 mm (W x H x D) (Depth of control panel interior: 60)
BCR2
48 x 96 x 68 mm (W x H x D) (Depth of control panel interior: 60)
BCD2
96 x 96 x 68 mm (W x H x D) (Depth of control panel interior: 60)
Control output
OUT1
R
Relay contact: 1a
S
Non-contact voltage (for SSR drive) 12 V DC 15%
A
Direct current: 4 to 20 mA DC
Power supply
voltage
0
100 to 240 V AC (Standard)
1
24 V AC/DC
Input
0
Multi-range (*1)
Option 1 (*2)
(Choose only one option.)
0
No option 1 needed.
1
EV2
Event output EV2 (*3)
2
DS
Heating/Cooling control output OUT2, Non-contact voltage
3
DA
Heating/Cooling control output OUT2, Direct current
4
P24
Insulated power output
Option 2 (*2)
(Choose only one option.)
0
No option 2 needed.
1
C5W (20A)
Event input (2 points) (*4) + Serial communication
+ Heater burnout alarm (20A) (*5)
2
C5W (100A)
Event input (2 points) (*4) + Serial communication
+ Heater burnout alarm (100A) (*5)
3
EIW (20A)
Event input (2 points) +
Heater burnout alarm (20A) (*5)
4
EIW (100A)
Event input (2 points) +
Heater burnout alarm (100A) (*5)
5
EIT
Event input (2 points) (*6)+
External setting input + Transmission output
6
C5
Serial communication
7
W (20A)
Heater burnout alarm (20 A) (*5)
8
W (100A)
Heater burnout alarm (100 A) (*5)
9
EI
Event input (2 points)
(*1) Thermocouple, RTD, Direct current and DC voltage can be selected by keypad.
(*2) Only one option can be selected from Option 1 and Option 2 respectively.
(*3) Event output EV1 is standard.
The following outputs can be selected in [Event output EV1/EV2 allocation] by keypad:
Alarm output (12 alarm types and No alarm action), Heater burnout alarm output, Loop break alarm output,
Time signal output, Output during AT, Pattern end output, Output by communication command, Heating/Cooling
control output OUT2 (for EV2 option only).
For Event output EV1/EV2, Heater burnout alarm output and Output by communication command are available
when C5W, EIW, C5 or W option is ordered.
(*4) For the BCS2, Event input (2 points) is not available.
(*5) For Direct current output type, Heater burnout alarm does not work.
(*6) For the BCS2, 1 point of Event input is available.