User Manual

40
6.2 Initial Setting Mode
To enter Initial setting mode, press and hold the and keys (in that order) for 3 seconds in RUN mode.
To set (or select) each setting item, use the or key.
To register each setting item, press the key.
Explanation of setting item:
Upper left: PV Display: Indicates setting characters.
Lower left: SV Display: Indicates factory default.
Right side: Indicates the setting item, explanation of its function, and setting range (or selection item).
Input type
Selects an input type from thermocouple (10 types), RTD (2 types), Direct current
(2 types) and DC voltage (4 types), and the unit / .
Characters,
Factory Default
Setting Item, Function, Setting Range
Input type
• Selects an input type from thermocouple (10 types), RTD (2 types), Direct current
(2 types) and DC voltage (4 type), and the unit / .
When changing the input from DC voltage to other inputs, remove the sensor
connected to this controller first, then change the input. If the input is changed
with the sensor connected, the input circuit may break.
When changing an input type, refer to Section 8.10 Items to be Initialized by
Changing Settings (p.96).
Selection item:
K -200 to 1370
K -328 to 2498
K -200.0 to 400.0
K -328.0 to 752.0
J -200 to 1000
J -328 to 1832
R 0 to 1760
R 32 to 3200
S 0 to 1760
S 32 to 3200
B 0 to 1820
B 32 to 3308
E -200 to 800
E -328 to 1472
T -200.0 to 400.0
T -328.0 to 752.0
N -200 to 1300
N -328 to 2372
PL- 0 to 1390
PL- 32 to 2534
C(W/Re5-26) 0 to 2315
C(W/Re5-26) 32 to 4199
Pt100 -200.0 to 850.0
Pt100 -328.0 to1562.0
JPt100 -200.0 to 500.0
JPt100 -328.0 to 932.0
Pt100 -200 to 850
Pt100 -328 to 1562
JPt100 -200 to 500
JPt100 -328 to 932
4 to 20 mA DC -2000 to 10000
0 to 20 mA DC -2000 to 10000
0 to 1 V DC -2000 to 10000
0 to 5 V DC -2000 to 10000
1 to 5 V DC -2000 to 10000
0 to 10 V DC -2000 to 10000
Scaling high limit
• Sets scaling high limit value.
• Setting range: Scaling low limit value to Input range high limit value
DC voltage, current inputs: -2000 to 10000 (*1)
(*1) The placement of the decimal point follows the selection.
Setting characters
Factory default value
Setting item name, function, setting range (or selection item)