User Manual
119
Circuit insulation
configuration
When the EIW or W option is ordered.
When the EIT or EI option is ordered.
When OUT1 is a non-contact voltage output or direct current output, and
when OUT2 is a non-contact voltage output or direct current output,
OUT1 is not electrically insulated from OUT2.
Insulation resistance: 10 M min., at 500 V DC
Dielectric strength
Between input terminal and power terminal: 1.5 kV AC for 1 minute
Between output terminal and power terminal: 1.5 kV AC for 1 minute
Between output terminal (P24) and power terminal: 500 V AC for 1 minute
POWER
SUPPLY
EV1
EV2
OUT2
P24
EXT
CONT
CPU
OUT1
TC
RTD
DC
TA
17
16
18
19
20
19
20
14
13
15
22
21
23
24
4
5
8 9 12 6 7
DI1
DI2
Electrically insulated
: When EIT option is ordered.
POWER
SUPPLY
EV1
EV2
OUT2
P24
CT1
CT2
CPU
OUT1
TC
RTD
DC
17
16
18
19
20
19
20
14
13
15
22
21
23
24
2
1
3
8 9 12
DI1
DI2
: When EIW option is ordered.
Electrically insulated