Specifications

YQE8-J0092E15
3.1.2 Thermal Head Power (THV) Setting
(1)
Measurement Conditions
Turn the Power on, and measure under ready condition.
(Ink Ribbon and Paper are not required with control PC board connected)
(2)
Setting Voltage
Open the Upper Cover, and read the THV value that is stated in the nameplate on the Thermal Head cover
(see below).
Close the Upper Cover.
Connect the digital voltmeter directly to the THV terminal (pin 1) and GND terminal (pin 10) of CN2
connector on DC Power Supply and set Power output under the following figure.
Set the voltage to +/- 0.1V limit to the THV value.
To set the THV value, use the THV variable volume described in Section 3.1.1.
(Turning the volume clockwise increases the voltage.)
3.1.3 +24V Verification
(1)Measurement Conditions
Be sure to perform the procedure for "+5V Setting" described in Section 3.1.1 first.
Turn the Power on, and measure under ready condition.
(Ink Ribbon and Paper are not required with control PC board connected)
(2)
Setting Voltage
Connect the digital voltmeter directly to the +24V terminal (pin 5 or 6) and P0V terminal (pin 7 or 8) of the
CN3 connector on DC Power Supply and set Power output under the following figure.
Verify whether the voltage is set at 24V +/- 1.44 V
If it is not set, replace DC Power Supply.
24.7V 4625Ω 0707000001
5B04 6038 TPH216R66
THV value