Owner Manual

Table Of Contents
8
NOTES
If a permanent drainage pipe is fitted,the unit will not stop operating. Setting the
desired
humidity to around 35% is good for laundry mode, a quick drying boost, or in
emergencies. It is not recommended for long normal operation in a domestic or office
environment.
To allow more moisture in the air, set a higher desired humidity
(e.g. 60%-70%).
We recommend setting the desired humidity to 50-55%. This is great for domestic operation
and dry storage.
Setting the humidity to 60% is great for personal comfort and applications where 50% RH is
considered too dry.
Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is
needed without the need to reduce the humidity further.
OTHER FEATURES AND INDICATORS
TANK FULL LIGHT
When the water tank is full, the unit will stop dehumidifying, the tank full light will illuminate and
the unit will bleep.
Empty the tank and reinsert it correctly to resume operation.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in
to defrost mode. Following completion of the defrost mode, the unit will return to the previously
operating settings.
When the unit is running in a room with a temperature between 32 and 53.6 (0 and
12)it will enter defrost mode for 8 minutes roughly every 30minutes.
When the unit is running in a room with a temperature between 53.6 and 60.8
(12and
16)it will enter defrost mode for 5 minutes roughly every 60minutes.
When the unit is running in a room with a temperature between 60.8 and 68 (16 and
20)it will enter defrost mode for 5 minutes roughly every 90minutes.
AUTO MODE
When the humidity of the room is 5% lower than the desired humidity the compressor will
turn off automatically .
When the humidity of the room is 5% higher than the desired humidity the compressor will
restart after a 3 minutes delay to protect the compressor.
POWER
After the unit has stopped, to protect the compressor, it is not recommended to resume
operation for at least 10 minutes. Operation can resume after this period lapses. When the
unit is restarted,there is a 3 minutes delay before compressor starting.