10. 160F (71C) TEMPERATURE SENSOR 
When this sensor (located on the left side firewall) reaches 160F (71C), the convection blower will go to high, 
cooling the unit. 
11. 120F (49C)- N/O TEMPERATURE SENSOR (SHUT DOWN SENSOR) 
This sensor (mounted on the exhaust blower housing) has two functions (only if the auto/manual switch is in the 
auto position): 
  -Should the fire happen to go out, this sensor will shut the stove off when the exhaust temperature drops 
below 120F (49C) 
  -When the auger is turned off via the Dial-A-Fire, the exhaust temperature will drop, when it goes below 
120F (49C), the sensor will turn the stove off. 
12. 120F (49C)-N/C TEMPERATURE SENSOR (IGNITER SHUT DOWN SENSOR) 
This sensor (mounted on the exhaust channel) will turn the igniter off when the exhaust channel temperature 
reaches 120F (49C). 
13. IGNITER 
Is a heating element used to ignite the fuel? When the start up switch is activated, the igniter is has power going 
to the igniter when the switch is in the manual position. Air passes through the igniter tube, which becomes super 
heated drying the fuel and then igniting the fuel through convection. 
14. VACUUM SWITCH 
This safety device (mounted on the left side pillar) detects vacuum in the exhaust system. If the exhaust blower 
fails or the vent pipe becomes plugged, this switch will sense that there is no airflow and will stop the auger from 
continuing to feed pellets. 