Item Brochure

18
B. TREE TRUNK PROTECTORS:
1. Product standard of quality: DeepRoot; ArborGard+
AG 9-4.
2. Material: 0.060" thickness polyethylene with UV
inhibitors, recyclable.
3. Size: 9" high by single length accommodating tree up
to 4" dia.
4. Larger trees indicated for protection: Couple two or
more sections together.
C. wATER BARRIERS:
1. Product standard of quality: DeepRoot; Water Barrier
WB Series.
2. Material: ** 0.030" ** 0.040" ** thickness High
Density Polyethylene (HPDE). (SELECT THICKNESS
DESIRED - DELETE OTHER)
3. Sizes: 24", 30", and 36" wide by 300'-0" rolls.
4. Manufacturer’s standard sealing tape.
5. Sealant: Silicone type recommended by water barrier
manufacturer for certain applications; applications
requiring sealant indicated in manufacturer’s product data.
D. STAKING AND GUyING MATERIALS:
1. Product standard of quality: DeepRoot; ArborTie+.
2. Material: Flat, woven polyproplyene; 900 lb. break
strength; 2,500 lb. break strength.
3. Size: ¾" wide by manufacturer’s standard roll lengths.
4. Color: ** Green. ** White. ** (SELECT COLOR)
2.03 ACCESSORIES
A . P R O v I D E R E L A T E D M A T E R I A L S F O R C O M P L E T E
INSTALLATION OF SPECIFIED MATERIALS.
PART 3 - EXECUTION
3.01 EXAMINATION
A. vERIFICATION OF CONDITIONS:
1. Verify other work in other sections, in, at, and around
landscaping work is complete to the extent that no
damage will occur to newly planted materials or, any
possible construction related damage will be minimal
and replacement plant material is readily available for
planting at no additional cost.
2. Obtain verification, in writing, from work required in
other sections directly involving work in this section
regarding correct grades have been provided, coordina-
tion of topsoil spreading, and lawns and grasses planting.
3. Beginning work without fulfilling conditions below
requiring removal or replanting work in this section
becomes responsibility of this section.
a. Not providing written notification to Architect of
unacceptable conditions indicates acceptance of site.
b. Not receiving verification indicated above.
c. Work required not indicated as unacceptable requiring
removal or replanting work.
3.02 PREPARATION
A . S U R F A C E P R O T E C T I O N :
Use methods necessary to prevent damage to completed
sitework performed in other sections. Protect access to
and areas around planted materials. Restore damaged
areas to original compaction, grades, and lines; repair
damaged grassed areas.
3.03 INSTALLATION
A . T R E E R O O T B A R R I E R S :
Install in accord with manufacturer’s reviewed installation
instructions where indicated on reviewed shop drawings
with vertical root directing ribs facing inwards towards
trees or plants; connect panels together as required.
B. TREE TRUNK PROTECTORS:
1. Install in accord with manufacturer’s reviewed installation
instructions where indicated on reviewed shop drawings.
2. Join two or more segments together for trees over 4" dia.
CSI SPECIFICATIONS
SECTION 02911
TREE, PLANT, AND hARDSCAPE PROTECTION