Upper Arm Blood pressure Monitor User Manual Model:SP10A/SP10B/SP10C Page 1 / 35
Table of Contents Foreword ................................................................................................................................................................... 3 Intended use ............................................................................................................................................................. 3 Intended users ...................................................................................................................................
Foreword Thank you for purchasing the Upper Arm Blood pressure Monitor. The blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. An oscillometric monitor does not need a stethoscope so the monitor is simple to use.
Read and save these instructions Before using your blood pressure monitor, please read this instructions and warnings completely. Warning For proper use of this product, please follow the warning information listed below: Cautions ◎ If the LCD displays a low voltage symbol, please charge it immediately. for power ● So as not to affect the use and damage the battery. source ◎ Please unplug the power supply when fully charged. PROHIBITI ● Otherwise, the monitor may be damaged.
◎ Do not measure blood pressure when common arrhythmias occur. ● Measurements may not be accurate or blood pressure may not be measured. ◎ it is dangerous for patients to self-judge and self-treat according to measuring results, so please follow your doctor's instructions. ● Self-judgment may make the illness worse. ◎ Do not use this product for newborns or infants and people who cannot express themselves, ● Otherwise, it may become the cause of accidents or disputes.
Other Suggestions: ※ this product will not interfere with the surrounding electrical and electronic products. ※ this product is not allowed to be tested and maintained on site. If there is any problem, please directly contact the company according to the contact information in this manual. ※ hint: any blood pressure measurement is influenced by the person's posture and his/her physical condition. Other factors that interfere with blood pressure measurement are: season, temperature, mood, environment, etc.
Blood pressure can vary depending on your condition. Therefore, please take your blood pressure measurement in a quiet and relaxing environment. At least twice a day, once in the morning and once in the evening. It is normal for blood pressure measured by a doctor or at a pharmacy to be different from that measured at home, depending on the environment in which it is measured.
Guidelines for the Management of Hypertension. J Hypertens, 1999, 17:151-185 4,Product introduction 4.1, Product structure The product is mainly consists of main unit and cuff. 4.2 LCD display ※The display will be different for different models, as shown in the table below. Display Backlight Applicable Model VA LCD Yes SP10A TN LCD Yes SP10B TN LCD No SP10C 4.3 Cuff This cuff is available in 22-32 cm; it contains air tube and cuff connector. The cuff is a consumable item.
Note: Do not use cuffs and other parts that are not specified by the manufacturer. Otherwise it may affect the measurement results 4.4 Specifications Product Name Upper Arm Blood pressure Monitor Models SP10A Measurement Principle Oscillometry Measurement site Upper arm Cuff Size 22cm~32cm Systolic Blood Pressure: 50~270 mmHg (6.7~36.0) kPa Measurement Range Diastolic Blood Pressure: 30~220 mmHg (4.0~29.3) kPa Pulse: 40~180 beats/minute Accuracy Pressure: ±3mmHg (±0.
Inflation Deflation Waterproof Degree of protection against electric shock Type of protection against electric shock Automatic inflation by internal pump Automatic speed deflation system controlled by internal electromagnetic valve. IP22 Type BF applied part Internally power equipment Mode of operation Continuous operation Software version V1.
Bluetooth Modulation Type GFSK Transmission type Wi-Fi Valid Transmission (Distance between Wi-Fi APP and Up to 10 meters blood pressure monitor) Wi-Fi APP running Enable smart devices running android 4 and above environment system version and iPhone 4s and above WIFI frequency 2412~2462MHZ WIFI frequency characteristic 2.4GHZ WIFI Modulation Type 802.11b: DSSS (CCK, DQPSK, DBPSK);802.
In case of the following, please charge immediately The icon " " of low battery indicator flashes, and the display shows" Lo ". The LCD does not display after pressing the button Warning We don't provide power adapter. Please purchase DC 5V1A power adapter which has passed IEC 60601-1 test. Do not use damaged power adapter, otherwise the monitor may be damaged or inaccuracy.
1) When the "Year" is flashing on the LCD, press the memory button “ press the user 2 button “ ” to confirm the setting, and enter the "Month" setting. 2) When the "Month" is flashing on the LCD, press the memory button “ press the user 2 button “ ” to increase the cycle of the hour, ” to confirm the setting, and enter the "Minute" setting.
3) Put upper left arm through the cuff. 4) Ensure the position of air mouth is at the inner side of the arm. and the extension line of the air hose should be aligned with the middle finger. Place the arm cuff 2~3cm above the elbow. 5) Pull one end of the cuff outward and tighten, fix the position of the cuff . Caution The cuff should be twined comfortably to the upper arm, there should be no gap between the arm and the cuff to prevent too tight or loose, it is advisable to reach into two fingers.
Caution: Do not take the measurement immediately after eating, drinking, smoking, exercising or showering, and wait at least 30 minutes before starting the measurement. Please take a rest at least 15 minutes before each measurement, and at least 2 minutes between continuous measurements. 6.2.3 Blood pressure measurement procedure 1) After the cuff has been appropriately positioned, press the User1 “ ” or User2 “ ” button to turn on the device.
Hint: Determine your blood pressure based on each measurement and the blood pressure table, and consult your doctor. 3) Take off the cuff from your arm and turn off the device by press the User1 “ ” or User2 “ ” button. (If there is no operation for 60 seconds, the device will be automatically off.
2) Press memory button “ ” again, the LCD display average measurement data as below: 3) Press memory button “ ” again, the LCD display the latest measurement data as below: 4) Every time you press the memory button briefly, you can look through the next set of measurement data in the order of measuring time from near to far, and you can view Max.99 sets of records of current user.
6.6 Wireless transmission function operation 6.6.1 APP Download and Installation Search "Runcobo note" in the App Store or other App markets to download and install the App. 6.6.2 APP installation Click "get" to install after verification. After the installation is successful, the "get" icon will change to "open".
X 6.6.3 APP Registration After installed the APP, open it and then complete registration follow the instruction on APP interface. 6.6.
Android phone: Turn on the Bluetooth and Position as below Figure: iPhone: Turn on the Bluetooth and limits of authority as below Figure: 2) Binding blood pressure monitor a) Click "Add Blood Pressure Monitor" and wait for the monitor to connect with APP as below figure: b) Turn on the monitor and start measure the blood pressure.
c) Don’t turn off the blood pressure monitor until the binding completed as below: 6.6.5 Connect with APP and blood pressure monitor via WiFi 1) Select 2.
3) Connect with blood pressure monitor a) Click "Immediate synchronization" and wait for the monitor to connect with APP as below figure: b) Turn on the monitor and start measure the blood pressure. When the measurement is finished, the blood pressure value is displayed on the LCD of monitor, and then APP will search the monitor automatically, When the APP connect with the monitor completely, the measurement data will synchronize as below figure: 6.6.
2) Click [Select] to delete the historical data follow below figure: 6.6.7 FAQ Click the "FAQ" on APP interface to see the help for frequently asked questions as below figures: XXX 6.6.
2)Click "update" to update 3)When "update" changes to "open", it means the update is complete, click "open" to open the app 7. Clean the monitor and cuff Clean the monitor and wrist cuff: 1) Make sure the monitor is off prior to cleaning.
2) Using a spray bottle, moisten a soft cloth towel with the neutral soap until it is fully saturated. Squeeze any excess water from the cloth to avoid any dripping of the monitor and wrist cuff. 3) Wipe all surfaces of the monitor and wrist cuff thoroughly, making sure to clean the inside and outside of the cuff. 4) Using a soft dry cloth, gently wipe away any excess moisture on the monitor and wrist cuff. Naturally dry the monitor and cuff. Note: Do not use any abrasive or volatile cleaners.
Problem Solution Button was pressed, but the monitor has no Please charge the device. If there is no charging indication, response Insert the reset hole with a needle object less than 1.5mm in diameter to reset the device. The device frequently fails to measure the 1. check the position of the cuff, and re-wrap the cuff at the blood pressure values, or the values correct position measured are too low or too high 2.
systems used in home healthcare environment IEC 80601-2-30 Medical Electrical Equipment - Part 2-30: Particular requirements for basic safety and essential performance of automated noninvasive sphygmomanometers ISO 81060-2 Non-Invasive Sphygmomanometers - Part 2: Clinical Validation of Automated Measurement Type EN 62304 Medical device software - Software life-cycle processes EN 62366 Medical devices – Application of usability engineering to medical devices EN ISO 10993-1 Biological evaluation of
Authorized representative in the European Community. Batch code SN Serial number Date of manufacture Keep dry Upward Fragile, handle with care Pile Limit 6 layers 14. Package list Only use original accessories. Check that the contents of the delivery are complete. Quantity Parts Part No. 1pc Main unit SP10A 1pc USB line 22-23 1pc Cuff(with Air hose) USB100032W 1pc User Manual / 15.
If Essential Performance is lost or degraded due to electromagnetic disturbances, this may result in inaccurate measurement and lead to mislead patients, please read below important information before to avoid possible electromagnetic disturbances.
in nearby electronic equipment. Conducted RF emissions Group 1 CISPR 11 Class B Radiated RF emissions Group 1 CISPR 11 Class B The monitor is suitable for use in all establishments, including domestic and those directly connected to the public low-voltage power supply network that supplies Harmonic emissions buildings used for domestic purposes except for near Class A IEC 61000-3-2 active HF surgical equipment and the RF shielded room for magnetic resonance imaging.
±0.5kV, ±1kV Surges lines to lines; IEC 61000-4-5 ±0.5kV, ±1kV, ±2kV Mains power quality should be that ±0.5kV, ±1kV of a HOME HEALTHCARE lines to lines; ENVIRONMENT or a Professional healthcare lines to earth facility environment.. 3V 0.15MHz – 80MHz, 6V in ISM bands between 0.15MHz and Conducted disturbances induced by RF fields IEC 61000-4-6 80MHz (Professional healthcare facility environment), 6V in ISM Applicable and amateur radio bands between 0.
NOTE: UT is the a.c. mains voltage prior to application of the test level. E.g.: 25/30 means 25 periods at 50 Hz or 30 periods at 60 Hz. Guidance and manufacture’s declaration – electromagnetic immunity The upper arm blood pressure monitor is intended for use in the electromagnetic environment specified below. The customer or the user of the upper arm blood pressure monitor should assure that it is used in such an environment.
5 240 5100 – 5800 5 500 WLAN 802.11 Pulse modulation b) a/n 217 Hz 0,2 0,3 9 5 785 NOTE If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m. The 1 m test distance is permitted by IEC 61000-4-3. a) For some services, only the uplink frequencies are included. b) The carrier shall be modulated using a 50 % duty cycle square wave signal.
has the right not to provide free maintenance service. For products that exceed the free warranty period and are not covered by the free regulations, spare parts and maintenance fees shall be charged. 17.FCC compliance statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Shenzhen,China Tel: 86-755-21635022 Customer service hotline : 86-400-998-2913 (service time: 9:00 to 21:00 of working day) Email: service@yolanda.hk Website: www.yolanda.hk Document No.: 20210501V1.0 User manual Edition:V1.0 Printed on: Feb.