Distanc between antannas and metal framed door >0.5m. Make
sure that metal frames in the vicinity of the system are electrically
connected together.
PRECAUTION
The system will best function if position away from cashier,
computer, data transmission line, power cable, fluorescent light,
etc. To maximize sensitivity, a distance of not less than 1.0m is
recommended.
PRECAUTION
To avoid any interference caused by other electronic appliances,
the system should be powered by an independent power source.
The power socket should adhere to safety standard and grounded.
PRECAUTION
Mono system will receive TX/RX system interference, in use at
least to ensure that with the TX/RX system between more than
10m from the safe distance.
PRECAUTION
As an example,a metal fence is not firmly fit together it could by a
small movement reach a capacitance between its parts so that it
acts as a perfect tag.If the signal has the same pattern as a label or
hardtag it would set the alarm off.
PRECAUTION
System Overview
The MONO Transceiver system is a multi-loop single panel 8.2MHz system that
provides enhanced detection when compared to a conventional system. It can
operate on its own or with multiple systems but without the need of
synchronization.. The installation is simple with just one tuning point for sensitivity.
Each panel have independent alarm and warning light.
Important Precautions