Users Manual

5.3 Icons in this Manual
Basic Operations
06
6.1 Instructions for Humidity Control
Setting(HS,HD,DD)
The PV Screen displays the measured value
of current humidity when working normally,
recognize and switch between
humidification mode and dehumidification
mode automatically.
.KYMJRJFXZWJI-ZRNINY^5;Ճ-ZRNINY^
Setting Value (HS)-Humidification Differential
Value (HD), the equipment will enter
humidification state, the red led is on, WORK1
output socket turns on. If the measured
-ZRNINY^5;Մ-ZRNINY^8JYYNSL;FQZJ-8
the red led is off, WORK1 output socket turns
off.
IconSymbol Function
Setting
Range
factory
Settings
Note
HS
Humidity Setting
Value
7-c7- 50.0%RH
HD
Humidification
Difference Value
7-c7- 5.0%RH 8JJ
DD
Dehumidification
Difference Value
7-c7- 5.0%RH
5.0%RH
8JJ
8JJ
8JJ
AH
Alarm High
Humidity Limit
7-c7- 7-
AL
Alarm Low
Humidity Limit
7-c7-
PT
Dehumidification
Delay Time
c2NSZYJX 0 Minute
CA Humidity Calibration 7-c7- 0.0%RH
13