User's Manual

detailed err_code)
9.10 Disconnect BLE
Example: “AT+disConnect\r\n”
Hex: 41 54 2B 20 64 69 73 43 6F 6E 6E 65 63 74 0D 0A
Replies: “AT+ok\r\n” (Operation completed); “AT+err_code\r\n” (Operation failed,
refer to“Returned error code indication”for detailed err_code)
9.11 Reset/Restart
Example: “AT+reStart\r\n”
Hex: 41 54 2B 20 72 65 53 74 61 72 74 0D 0A
Reply: “AT+ok restart now \r\n” (Operation completed, restart at once automatically)
9.12 Read Parameter
Example: “AT+getPara\r\n”
Hex: 41 54 2B 20 67 65 74 50 61 72 61 0D 0A
Reply: “AT+ok uart 9600,8,N,1; adv 120 160; con 36,24,2,300.\r\n” (Operation
completed), returned parameter contains UART port, broadcast interval,
connection interval.
9.13 Exit Command Mode
Example: “AT+exit\r\n”
Hex: 41 54 2B 20 65 78 69 74 0D 0A
Reply: “AT+ok Mode=Normal\r\n” (Operation completed, switches to transparent
transmission mode)
9.14 Shut Down
Example: “AT+shutDown\r\n”
Hex: 41 54 2B 20 73 68 75 74 44 6F 77 6E 0D 0A
Reply: “AT+ok power off now!\r\n”(Operation completed)
9.15 Factory reset
Example:“AT+reStore\r\n”
Hex: 41 54 2B 20 72 65 53 74 6F 72 65 0D 0A
Reply:AT+ ok restart now\r\n(Operation completed)
9.16 Version inquiry
Example:“AT+getInfo\r\n”
Hex: 41 54 2B 67 65 74 49 6E 66 6F 0D 0A
Reply:AT+ok HW=XW32-BLE-BLE-JXKJ,SW=V0.2
9.17 Instruction help
Example: “AT+help\r\n”
Hex:41 54 2B 20 68 65 6C 70 0D 0A
Reply:AT+ok Help:
system_shutdown
setBR
getName
setName
getAddr
setAddr
getStatus
setAdvInt
setConnInt
disConnect
reStore
reStart
getPara