Use Instruction
Table Of Contents
- 1.Introduction
- 2.Product introduction
- 3.Preparation before use
- 4.How to use
- 4.1Before use
- 4.2ECG lead wire, temperature probe and blood oxygen
- A.Use of ECG lead wire, body temperature probe and
- B.ECG lead wire placement
- Lead
- Color
- Body surface position (common name)
- 12-lead electrode cable
- RA
- White
- Intersection point between the midline of the righ
- LA
- Black
- The intersection of the left midline of the clavic
- RL
- Green
- Right lower abdomen (right leg)
- LL
- Red
- Left lower abdomen (left leg)
- V1
- Red
- Thoracic lead V1: the fourth intercostal space at
- V2
- Yellow
- Thoracic lead V2: the fourth intercostal space at
- V3
- Green
- Chest lead V3: midway between V2 and V4
- V4
- Blue
- Thoracic lead V4: midclavicular line at the fifth
- V5
- Orange
- Chest lead V5: at the front axillary line, at the
- V6
- Purple
- Chest lead V6: at the mid-axillary line, at the sa
- 6 lead electrode cable
- RA
- White
- Intersection point between the midline of the righ
- LA
- Black
- The intersection of the left midline of the clavic
- RL
- Green
- Right lower abdomen (right leg)
- LL
- Red
- Left lower abdomen (left leg)
- V1
- Red
- Thoracic lead V1: the fourth intercostal space at
- V5
- Orange
- Chest lead V5: at the front axillary line, at the
- 5 lead electrode cable
- RA
- White
- Intersection point between the midline of the righ
- LA
- Black
- The intersection of the left midline of the clavic
- RL
- Green
- Right lower abdomen (right leg)
- LL
- Red
- Left lower abdomen (left leg)
- V1
- Red
- Thoracic lead V1: the fourth intercostal space at
- 3 lead electrode cable
- RA
- White
- Intersection point between the midline of the righ
- LA
- Black
- The intersection of the left midline of the clavic
- LL
- Red
- Left lower abdomen (left leg)
- C.Spo2 probe placement
- D.Temperature probe placement
- 4.3Measurement process
- 4.4Data view
- 4.5 Charging
- 5.Care and maintenance
- 6.Attachment list
- Appendix A Specifications
- Appendix B Electromagnetic compatibility
2
immediately.
If you have a pacemaker in your body, we do not recommend that
you use this device. Follow your doctor’s advice if necessary.
This equipment cannot be used simultaneously with defibrillators
and electrosurgical equipment.
This equipment cannot be used during CT or MRI.
When using this equipment, please stay away from equipment that
generates strong electric and magnetic fields. Using this device in an
inappropriate environment may cause interference to surrounding
radio devices or affect the operation of this device.
This equipment cannot be used in a flammable environment (such as
an oxygen-rich environment).
This device cannot be used by babies weighing less than 10 kg.
Do not swim or submerge the device in water. Do not immerse the
device in water or other liquids. Please pay attention to
waterproofing and keep it away from high temperature and
humidity.
Do not use acetone or other volatile solutions to clean the
equipment.
Do not violently bump or squeeze the device, if the shell is broken,
please stop using it.
Do not place this equipment in a pressure vessel or gas sterilization
equipment.
Do not disassemble the equipment at will, otherwise it will cause the
machine to malfunction or affect the normal operation of the
equipment.
Please place the device out of the reach of children.
Be careful of strangulation of cables and hoses due to excessive
length.
This device cannot be used on people with sensitive skin or
allergies.
This equipment cannot be placed in the following environments:
direct sunlight, high temperature, high humidity, close to water or
fire, high electromagnetic influence. Before using the equipment,
you must ensure that the equipment is in a normal working
condition and operating environment.