Use Instruction
Table Of Contents
- 1.Introduction
- 2.Product introduction
- 3.Preparation before use
- 4.How to use
- 4.1Before use
- 4.2ECG lead wire, temperature probe and blood oxygen
- A.Use of ECG lead wire, body temperature probe and
- B.ECG lead wire placement
- Lead
- Color
- Body surface position (common name)
- 12-lead electrode cable
- RA
- White
- Intersection point between the midline of the righ
- LA
- Black
- The intersection of the left midline of the clavic
- RL
- Green
- Right lower abdomen (right leg)
- LL
- Red
- Left lower abdomen (left leg)
- V1
- Red
- Thoracic lead V1: the fourth intercostal space at
- V2
- Yellow
- Thoracic lead V2: the fourth intercostal space at
- V3
- Green
- Chest lead V3: midway between V2 and V4
- V4
- Blue
- Thoracic lead V4: midclavicular line at the fifth
- V5
- Orange
- Chest lead V5: at the front axillary line, at the
- V6
- Purple
- Chest lead V6: at the mid-axillary line, at the sa
- 6 lead electrode cable
- RA
- White
- Intersection point between the midline of the righ
- LA
- Black
- The intersection of the left midline of the clavic
- RL
- Green
- Right lower abdomen (right leg)
- LL
- Red
- Left lower abdomen (left leg)
- V1
- Red
- Thoracic lead V1: the fourth intercostal space at
- V5
- Orange
- Chest lead V5: at the front axillary line, at the
- 5 lead electrode cable
- RA
- White
- Intersection point between the midline of the righ
- LA
- Black
- The intersection of the left midline of the clavic
- RL
- Green
- Right lower abdomen (right leg)
- LL
- Red
- Left lower abdomen (left leg)
- V1
- Red
- Thoracic lead V1: the fourth intercostal space at
- 3 lead electrode cable
- RA
- White
- Intersection point between the midline of the righ
- LA
- Black
- The intersection of the left midline of the clavic
- LL
- Red
- Left lower abdomen (left leg)
- C.Spo2 probe placement
- D.Temperature probe placement
- 4.3Measurement process
- 4.4Data view
- 4.5 Charging
- 5.Care and maintenance
- 6.Attachment list
- Appendix A Specifications
- Appendix B Electromagnetic compatibility
1
1.
Introduction
Thank you for purchasing a wireless dynamic
multi-parameter holter (hereinafter referred to as: holter).
This manual describes the purpose, function and safe use of
the equipment. Before using this equipment, please read
carefully and fully understand the contents of this manual to
ensure the correct use of this equipment and the safety of
patients and operators. Our company can provide circuit
diagrams, component lists, legends, calibration rules, or other
information necessary for qualified technicians to help users
repair equipment parts designated by the manufacturer as
repairable.
This product does not have the function of identifying stop
blog and ST.
Software release version: V1
1.1 Safety information
Caution
Before using this equipment, please read this manual carefully and
fully understand the relevant warnings and risks.
This device cannot replace the medical diagnosis results of
professional doctors.
The measurement results of this equipment are for reference only
and cannot be directly used as a basis for clinical treatment.
The disposable ECG electrodes used in conjunction with this device
are accessories purchased by the user and must be a regular device
with a medical device registration certificate.
Single-use ECG electrodes cannot be attached to the patient's
wounded or scarred skin.
Single-use ECG electrodes should be in close contact with the skin.
If itching or skin allergies or ulcers occur, stop using them