User Guide

TRL1safetyinterlockingdeviceseriesindicatorstatus
NoRFIDtag(commoncode)
NoRFIDtag(uniquecode)
RFIDtag,noLOCKsignal
RFIDtags,doorlock,noinputsignals
RFIDtags,doorlock,noinputsignals
Alwayson
Flashinglight
Alwayson
Off
Off
Greenlight
INPUT
YellowLight
LOCK
YellowLight
Redlight
Productstatus
LEDstatusduringnormaloperation
Off
Off
Off
1Hzflash
Alwayson
Off
Off
Off
1Hzflash
Alwayson
Off
Off
1Hzflash
Alwayson
Alwayson
OSSDoutputoverload/AUXoutputoverload/OSS
outputselfdiagnosisfault/OSSterminalvoltage
detectionfault
1Hzflash
1Hzflash
4Hzflash
4Hzflash
3redand1greencyclicflashing
3greenand1redcyclicflashing
Redgreenalternating1Hzflashing
Redgreenalternating4Hzflashing
Greenlight
Redlight
Productstatus
LEDstatusduringfault
Off
Off
Off
Off
Off
Red/greenlight
Red/greenlight
LOCK
INPUT
Uniqueencodingactuatorusesmatching
TRL1safetylocksareclassifiedintogenericanduniquecodingtypes.
UniqueCodeTypeTheTRL1safetydoorlockhasnouniquecodebeforedelivery.Youneedtomatchthecode
withtheTRL1actuator(doorkey)onlywhenyouuseitforthefirsttime.
Afterthegreenlightflashesthreetimes,theredlightflashesfor1s,thenflashestwiceat2Hz,andrepeat.Theother
lightsareoff(uniquecode).
Forsensorsthathavenotcompletedcodingmatching,codingmatchingshallbeperformedasfollows:
①UsetheTRL1actuator(doorkey)providedbyourcompanytoinserttheunmatchedTRL1safetydoorlock;
②Poweron the TRL1 safetylock. Afterthe TRL1 safety lock thatdoes notmatchthe code is powered on and
initialized successfully (the green light blinks three times), it enters the matching mode, and the traffic light blinks
alternatelyandrapidly.
③TRL1safetydoorlockwillreadthecodeofTRL1actuator(doorkey);
④After5 seconds,the TRL1 safetydoor lock matches the codesuccessfully, and the trafficlights stop flashing
alternately;
⑤PleasepoweroffandrestarttheTRL1safetylock.
※OncetheuniquecodetypeTRL1safetydoorlockmatchesthecodeofaTRL1actuator(doorkey)successfully,thisTRL1safetydoorlockcanonlyidentifythematchedTRL1actuator(door
key),butnototherTRL1actuators(doorkey)duringuse.
INPUT
YellowLight
LOCK
YellowLight
1Hzflash
4Hzflash
Off
Off
Off
Off
Off
Off
Off
Off
1Hzflash
Alwayson
Off
Off
Off
Powersupplyvoltageoutofoperatingrange
Inputselfdiagnosisfault
Electromagnetfault/optocouplerselfdiagnosis
fault
Openingtimeout
Doorlocktimeout
CommunicationfailureofmainandauxiliaryMCU
Uniquecodelabelanddoorlockcodedonot
match
Theactuatormustbematchedforthefirstuse.
Intheprocessofactuatormatching,donotpowerofformovetheactuator,
otherwisethematchingwillfail.
Aftermatchingtheactuatorandinductor,theycanonlybeusedinpairs,andthe
inductorcannolongeridentifyotheractuators.
Attention
SHENZHENTONGCHUANGMECHANTRONICSCO.,LTD.