5.2 General Operations for ADAS Calibration
5.2.1 Precondition for the use of the ADAS calibration tool
Vehicle system is working properly.
No trouble codes (not including the ADAS-related trouble codes) stored in ECU
memories.
Prepare X-431 ADAS Mobile / X-431 ADAS PRO calibration tool and vehicle-
Front & rear axle track is properly adjusted.
5.2.2 Workstation requirements
To make you work smoothly and calibrate accurately, please make sure the following
workstation requirement are met.
The lighting system around the calibration workstation should be a non-frequency
flash source, including but not limited to: LED light source, industrial lighting
complying with international standards, dual light source in opposite phase.
camera, otherwise the camera will reduce the exposure so that the captured
panel.
The light source should ensure uniform illumination distribution in the calibration
workstation.
The brightness of the light should not be changed, and ensure that there will be no
other changing light source around the workstation, such as a driving vehicle with
lights ON, etc.
5.3 Calibration Operation
The calibration operation should be performed strictly following the on-screen
instructions on the diagnostic tool. For some vehicle models, calibration pattern and
calibration tool are not mandatory. But for some camera-based ADAS, the calibration
cannot be done without the help of calibration tool and calibration pattern. In this
case, for the positioning of the calibration tool and vehicle, it is necessary for the user