CAT-601S Auto Transmission Cleaner and Fluid Exchanger User’s Manual
12
Fig.30(b)
9.1 Sensor calibration
1) Select the item for sensor calibration, press OK key
to OK the sensor calibration menu as shown in
Fig.31.
Fig.31
2) Press OK key to select the item for new fluid tank
calibration, the interface is as shown in Fig. 32.
Fig. 32
3) According to the prompts on the interface, OK the
weight value of the weight, and then press OK key.
The interface is as shown in Fig.33.
Fig.33
4) Remove the new fluid tank. When the value
displayed on the interface is stable, please press OK
key to save the data. The interface is as shown in
Fig.34.
Fig.34
5) Put the weight on the plate. When the value
displayed on the interface is stable, please press OK
key to continue. The interface is as shown in Fig.35.
Fig.35
6) When the value displayed on the interface is stable,
please press OK key again to save the data. The
interface is as shown in Fig.36.
Fig.36
7) Remove the weight, and then place the empty new
fluid tank on the plate. When the value displayed on
the interface is stable, please press OK key to save
the data. The sensor calibration for new fluid tank is
completed. When filling the new fluid into new tank,
the display screen will display the quantity of the fluid.
The calibration way for used fluid tank is the same as that
of the new fluid tank.
8) Select “Temperature Sensor” calibration item in Main