AlarmMessage
Allalarmsareshowninthedisplay.Whenanoperationparameterexceedsthe
presetvalue,itwillbedisplayedinREDasawarning.
1. CableLinkDisconnect
Whenacablelinkisdisconnected,itisdisplayedintheRedicon
【Link】:indicating
cablelinkhasbeendisconnected,pleasecheckthecableandsettings.
2. ForwardPowertooLow
Whenyouhavesettheminimumpowerviathesoftware,thebasestationwill
automaticallyadjusttheTXfrequency,whichmustbehigherthantheminimum
power.Whenthebasestationfailstoreachthisfr
equency,however,thedisplay
willshowthealarm.Forexample,theminimumpowerissetat5W,whilethe
basestationcanonlyoperateat5Wcurrently,thealarmisshownas
【pow:
5W】.
3. HighTem peratureAlarm
Whentheworkingtemperatureofbasestationishigherthanthevaluesetvia
software, it will show the high temperature alarm. For example, the high
temperaturethresholdissetat70℃,whenthetemperatureofbasestationis
75 ℃, the temperature is displayed as
【 】. You need to move the base
stationtoadryandcoolplacetofacilitatedissipation.Orshutdownthepower,
andterminateitsoperationathighpower.
4. HighReflectionAlarm
Whenthereversepowerisgreaterthanthepowersetviasoftware,itwillshow
thehighreflectivewarningicon
【Pow:20W0.0】.Youneedtocheckthefeeder
connectingtothepoweramplifierport,thefrequencybandofduplexer,andthe
matchnessofantenna,etc.